5 Putting into operation
BRS-CC
7
Fasten the adjusted motor position by means of the screws
8
Move the torch out the clamping device
and remove the distance sleeve
from the
milling cutter
.
5.8 Establishing the electrical connection
Four robot outputs 24 V DC and one robot input 24 V DC are required for controlling the valve.
NOTE
The cleaning station must be and remain without pressure and tension during setup!
• The gas nozzle diameter must match the one of the prism.
• The distance sleeve must match the nominal diameter of the gas nozzle.
• The milling cutter must be adapted exactly to the torch type.
Fig. 10
Electrical connection
XPE1
PE
13
25
47
69
81
1
10
13
12
15
14
Y4
Y2
Y3
Y1
S1
X1
S1
Y4
X5.
1
X5.2
X1
.4
Y2
X3.2
X3.
1
X1
.2
Y3
X4.2
X4.
1
X1
.3
Y1
X2.
1
X2.2
X1
.1
Signals: Lift down
Valves: clamp, motor
Cutter
Lift
Injection
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
24 V DC
GND