Fields in the ADSL Configuration Current Line Speed menu
Field
Description
Downstream
Displays the data rate in the receive direction (direction from
CO/DSLAM to CPE/router) in bits per second.
The value cannot be changed.
Upstream
Displays the data rate in the send direction (direction from CPE/
router to CO/DSLAM) in bits per second.
The value cannot be changed.
Fields in the ADSL Configuration ADSL Parameters menu
Field
Description
ADSL Mode
Select the ADSL mode.
Possible values:
•
Automatic Mode
(default value): The ADSL mode is auto-
matically adapted for the remote terminal.
•
ADSL1
: ADSL1 / G.DMT is used.
•
ADSL2
: ADSL2 / G.992.3 is used.
•
ADSL2 Plus
: ADSL2 Plus / G.992.5 is used.
•
None
: The ADSL interface is not active.
Transmit Shaping
Select whether the data rate in the send direction is to be re-
duced. This is only needed in a few cases for special DSLAMs.
Possible values:
•
Default (Line Speed)
: The data rate in the send direc-
tion is not reduced.
•
128,000 bps
to
2,048,000 bps
: The data rate in the send
direction is reduced to a maximum of 128,000 bps to
2,048,000 bps in defined steps.
•
User Defined
: The data rate is reduced to the value
entered in Maximum Upstream Bandwidth
The default value is
Default (Line Speed)
.
Maximum Upstream
Bandwidth
Only if Transmit Shaping =
User defined
6 Physical Interfaces
Funkwerk Enterprise Communications GmbH
126
bintec R200 Series