EN
77-3095-R1.0 (8/2015)
4 / 8
Verify the wiring inside the barrier box by referring to the tables below. See the
77-2983 Maintenance &
Repair Manual
for a wiring diagram and enclosure locations.
Installation
The remote color change box is designed to be used inside a hazardous environment, such as a spray
booth, however, the Zener barrier box must remain with the GEMS control in the non-hazardous area.
Mount the barrier box to the GEMS mast as described below.
Mount the barrier box to the GEMS mast using the
mounting bracket and supplied bolts and nuts, as
shown.
Installation should be performed by a qualified electrician. Improper installation could create a
spark, resulting in fire or explosion.
!
WARNING
TABLE B—ENCLOSURE WIRING
WIRE
NUMBER
& COLOR
ENCLOSURE
LOCATION
DESCRIPTION
219
RED
L2C14
+24v
322
WHITE
L3D7
Signal
276
BLACK
L2C24
DCC
none
GREEN
ground
TABLE A—BARRIER WIRING
WIRE
NUMBER
& COLOR
BARRIER
TERMINAL
(1-8)
219
RED
8
322
WHITE
5
276
BLACK
6
none
GREEN
GRD foot
4421
RED
1
4441
WHITE
4
DCC
BLACK
3