Remove#354
Jumper to location B13
EN
77-3095-R1.0 (8/2015)
6 / 8
Mount the in-booth color change box in the desired location,
ensuring adequate cable length for the installation.
For reference, note the barrier terminal connections for the
inbooth color change box. Verify the wires 4441, 4421, and
DCC are connected properly according to table C.
TABLE C—COLOR CHANGE
BOX WIRING
WIRE NUMBER
BARRIER
TERMINAL
4441
4
4421
1
DCC
3
Run the required length of pneumatic tubing for the color change
box. The 5/32” tubing should enter the GEMS enclosure in the top
right bulkhead, when viewed from the back side. This will connect it
to solenoid TRG2 which now needs to be rewired.
For the pneumatic indicator to signal alarms, the wiring must be
adjusted slightly. The TRG2 solenoid will become the pneumatic
indicator solenoid. Remove wire #354 completely and replace it with
jumper wire #341. One end should connect into terminal B13 and
the other end should go into the board slot with existing wire #341.