background image

 

Rotary Switch

 

 

Push Button

Pneumatic Indicator

EN

77-3095-R1.0  (8/2015)

7 / 8

Remote Color Change Operating Instructions

LOADING OR CHANGING A COLOR:

 When a color change or load is required, shut off atomizing air to 

the spray gun. Turn the rotary switch to the desired color number, and press the push button for 5 seconds 

until the flushing and / or loading process begins. Trigger the gun into a grounded metal waste container. 

Flow will stop when the paint is loaded and ready to spray. Engage atomizing air to begin spraying.

ALARMS:

 The pneumatic indicator will show when the unit is in alarm mode. To silence and reset the 

alarm, press the push button. If the alarm repeats, the operator should return to the GEMS control and 

resolve the alarm at the touch screen.

USING WITH FLUSH BOXES: Place the gun in the flush box and close the lid completely before starting 

a color change or load.

The remote color change box is designed to only be used with single gun systems.  

It cannot be used with two spray guns.

NOTE

Summary of Contents for GEMS 240-3053-1

Page 1: ...EN 77 3095 R1 0 8 2015 1 8 OPERATION MANUAL 240 3053 1 REMOTE COLOR CHANGE BOX INSTALLATION INSTRUCTIONS GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONENT MIXING SYSTEM...

Page 2: ...ays follow the pressure relief procedure in the equipment instruction manual NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment STATIC CHARGE Fl...

Page 3: ...for in booth capability of Remote color change box Paint flow meter on GEMS fluid panel Solvent flow meter on GEMS fluid panel This manual describes the installation of the barrier box and remote colo...

Page 4: ...the barrier box to the GEMS mast as described below Mount the barrier box to the GEMS mast using the mounting bracket and supplied bolts and nuts as shown Installation should be performed by a qualifi...

Page 5: ...2015 5 8 The barrier box cable 240 3072 3 will connect to the terminals indicated here Reroute the new harness into the enclosure and connect wires 219 276 and 322 in the correct terminal positions as...

Page 6: ...ERMINAL 4441 4 4421 1 DCC 3 Run the required length of pneumatic tubing for the color change box The 5 32 tubing should enter the GEMS enclosure in the top right bulkhead when viewed from the back sid...

Page 7: ...tal waste container Flow will stop when the paint is loaded and ready to spray Engage atomizing air to begin spraying ALARMS The pneumatic indicator will show when the unit is in alarm mode To silence...

Page 8: ...an authorized distributor contact one of our international sales and customer support locations below USA Canada www binks com info carlisleft com Tel 1 800 992 4657 Fax 1 888 246 5732 United Kingdom...

Reviews: