BARRIER BOX

 

REMOTE COLOR 

CHANGE BOX 

EN

77-3095-R1.0  (8/2015)

3 / 8

Remote Color Change Box

The remote color change box is used with the GEMS system for in-booth control of flushes, color changes, 

and alarm resets.

For proper operation of this accessory the GEMS system requires a Zener barrier wired in series with the 

electrical component used in the hazardous area. The barrier is installed in a box attached to the back of 

the GEMS control enclosure. The box can accept up to three barriers for in-booth capability of:

• Remote color change box

• Paint flow meter (on GEMS fluid panel)
• Solvent flow meter (on GEMS fluid panel)

This manual describes the installation of the barrier box and remote color change box. For information on 

installation of the barriers for in-booth use of the flow meters, see manual 77-3094: Zener Barrier Box 

Installation

.

240-3053-1 Package Contents:

• Remote color change box with 50’ [15m] cable
• NEMA 4 barrier box with mounting hardware
• Zener barrier with associated wiring

Note this part number does not include a barrier for in-booth operation of the paint flow meter. To order a 

package for in-booth color change and fluid panel capability, order part # 240-3053-2

.

Summary of Contents for GEMS 240-3053-1

Page 1: ...EN 77 3095 R1 0 8 2015 1 8 OPERATION MANUAL 240 3053 1 REMOTE COLOR CHANGE BOX INSTALLATION INSTRUCTIONS GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONENT MIXING SYSTEM...

Page 2: ...ays follow the pressure relief procedure in the equipment instruction manual NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment STATIC CHARGE Fl...

Page 3: ...for in booth capability of Remote color change box Paint flow meter on GEMS fluid panel Solvent flow meter on GEMS fluid panel This manual describes the installation of the barrier box and remote colo...

Page 4: ...the barrier box to the GEMS mast as described below Mount the barrier box to the GEMS mast using the mounting bracket and supplied bolts and nuts as shown Installation should be performed by a qualifi...

Page 5: ...2015 5 8 The barrier box cable 240 3072 3 will connect to the terminals indicated here Reroute the new harness into the enclosure and connect wires 219 276 and 322 in the correct terminal positions as...

Page 6: ...ERMINAL 4441 4 4421 1 DCC 3 Run the required length of pneumatic tubing for the color change box The 5 32 tubing should enter the GEMS enclosure in the top right bulkhead when viewed from the back sid...

Page 7: ...tal waste container Flow will stop when the paint is loaded and ready to spray Engage atomizing air to begin spraying ALARMS The pneumatic indicator will show when the unit is in alarm mode To silence...

Page 8: ...an authorized distributor contact one of our international sales and customer support locations below USA Canada www binks com info carlisleft com Tel 1 800 992 4657 Fax 1 888 246 5732 United Kingdom...

Reviews: