FED (E2) 12/2014
page 47/55
Unit size
53
115
240
400
720
Ventilation data
Air change
at 70 °C /
158 °F
x/h
***
29
19
17
11
at 150 °C /
302 °F
x/h
43
32
20
18
12
at 300 °C /
572 °F
x/h
66
26
18
16
10
Electrical data
IP system of protection acc. to EN 60529
20
20
20
20
20
Nominal voltage (±10 %) 50/60 Hz
V
230 1N~ 230 1N~ 230 1N~ 400 3N~ 400 3N~
Nominal power
kW
1.20
1.60
2.70
3.40
5.00
Energy
consumption
at 70 °C /
158 °F
Wh/h
162
230
370
520
570
at 150 °C /
302 °F
Wh/h
397
544
850
1200
1320
at 300 °C /
572 °F
Wh/h
933
1100
1400
2340
2600
Unit fuse 5 x 20 mm
230V / 10A / middle-time-lag (M)
A
10 A
external
10 A
external
16 A
external
--
--
Over-current release category B
--
--
--
3 x 16A
internal
3 x 16A
internal
Power plug
shock proof plug
CEE plug 5 poles
Installation category acc. to IEC 61010-1
II
II
II
II
II
Pollution degree acc. to IEC 61010-1
2
2
2
2
2
Electrical connection data FED-UL constructed acc. to cUL standard (for USA and Canada)
Unit size
53-UL
115-UL 240-UL 400-UL 720-UL
Electrical data
Nominal voltage (±10%) 60 Hz
V
115 1N~ 115 1N~ 208 3N~ 208 3N~ 208 3N~
Power plug
NEMA
5-20P
5-20P L21-20P L21-20P L21-20P
Nominal power
kW
1.20
1.60
2.70
3.40
5.00
Unit fuse 6,3 x 32 mm
250V / super-time-lag TT
A
16
16
16
16
20
external external
3 x
internal
3 x
internal
3 x
internal
Legend:
1) without outer glass door 2) up to 98 % of the set value
All technical data is specified for unloaded units with standard equipment at an ambient temperature of
+25 °C and a power supply voltage fluctuation of ±10. The temperature data is determined in accordance
to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 %
of the height, width and depth of the inner chamber. Technical data refer to 100% fan speed.
All indications are average values, typical for units produced in series. We reserve the right to
change technical specifications at any time.
If the cabinet is fully loaded, the specified heating up times may vary according to the load.
12.5 Equipment and Options
To operate the drying and heating oven FED, use only original BINDER accessories or
accessories / components from third-party suppliers authorized by BINDER. The user is
responsible for any risk arising from using unauthorized accessories.
Unit size
53
115
240
400
720
Standard equipment
Microprocessor temperature controller with LED
display and several time functions
Controller Timer functions: Delayed ON, delayed
Off and temperature dependent delayed OFF