1-51
D70E
9.2 Strings
The terminal is equipped with two serial outputs with RS232 (via
COM1) and Ethernet standards.
Via COM1, the following strings are available: ESTESA, CB,
PRINT,CMA, ESTNUM, STRCPE.
Via Ethernet, the following strings are available: ESTESA, CB..
9.2.1 Cb (or Bilanciai) string
The transmitted weight is net.
1st character $(24H)
start string character
2
nd
character <s>
s=stability
s=0 weight stable
s=1 weight not stable
s=3 weight not valid (negative or
overload)
3
rd
– 7
th
character
net weight if the weight consists of
more than 5 digits, the least
significant
digits
will
not
be
transmitted;
8
th
character <CR>(ODH) end string character
The following protocols are available: Cyclic (see par. 9.3.2 on page 1-68)
and ACK-NAK (see par. 9.3.1 on page 1-68).
Serialization:
1 start bit
7 datum bits
EVEN parity
2 stop bits
speed 4800 baud
There is a 300 ms ± 10% pause between the end of one string and the
beginning of the next.
Summary of Contents for D70E