8.5.3
ELECTRIC PUMP
PROBLEM
PROBABLE CAUSE
REMEDY
The lifting
platform during
the ascent and/or
descent vibrates
excessively or
Air present in the Hydraulic
circuit.
It is necessary to bleed the hydraulic circuit
by lifting and lowering the lifting platform a
few times.
The lift climbs
slowly
and
with difficulty
Oil too viscous
If the air temperature falls below -6°/-10° C,
the oil decreases its fluidity. To solve this
problem, lift and lower the lift a few times
so that the oil increases its temperature.
Operating on the
button panel, the
motor runs but the
lift does not rise.
Oil level in the pump too low.
Remove the casing of the pump and check the oil
level through the plug
(Figure 14). If the level is
too low, add ISO VG 10 hydraulic oil.
Hydraulic pump problems
Contact the dealer or Bike-Lift - Europe s.r.l.
Operating on the
button panel the
motor does not
run
The emergency stop (red
button in case of the built-in
lifting platform version) on
the button panel is inserted
Release the red button on the button panel
by turning it clockwise.
No voltage
Check the mains connection plug
Improper operation of the
button unit on the button
panel
Replace the button unit
The motor is short-circuited
Contact the dealer or Bike-Lift - Europe s.r.l.