AS-i/Modbus Gateway
Address-Table of the Modbus Interfaces
Subject to reasonable modifications due to technical advance.
Copyright Bihl+Wiedemann, Printed in Germany
Bihl+Wiedemann GmbH · D-68199 Mannheim · Tel. +49-621-339960 · Fax +49-621-3392239 · Internet http://www.bihl-wiedemann.de
is
s
u
e
d
a
te
1
1
.1
.2
0
0
0
50
In the lower 4 bits (2
0
to 2
3
) of the permanent configuration data the identification-
code resides, in the second lower nibble (2
4
to 2
7
) the I/O-configuration.
Parameters Projected
(PP)
Address
Data element
200
201
202
...
230
231
projected par. of slave 0
projected par. of slave 1
projected par. of slave 2
...
projected par. of slave 30
projected par. of slave 31
Permanent Config. Data
(PCD)
Address
Data element
300
301
302
...
330
331
permanent conf. of slave 0
permanent conf. of slave 1
permanent conf. of slave 2
...
permanent conf. of slave 30
permanent conf. of slave 31
Execution Control and Host Interface Flags
Address
Bit
Data element
399
0
1
2
3
4
5
6
7
“Config_OK”
“LDS.0”
“Auto_Address_Assign”
“Auto_Address_Available”
“Configuration_Active”
“Normal_Operation_Active”
“APF / not APO”
“Offline_Ready”
399
8
9
10
“Data_Exchange_Active”
(inverted!)
“Off-line”
“Auto_Address_Enable”
(inverted!)
unpacked AS-i Control user memory
Address
Data element
400
401
402
...
525
526
527
byte M 0
byte M 1
byte M 2
...
byte M 125
byte M 126
byte M 127