- 23 -
INST
ALLA
TION
TECHNICAL INFORMATION
Gas restrictors references
Ø mm
/100
Natural G20
565
Propane G31
430
Air/gas mixer restrictors
Natural G20
Fuch
-
sia
Fucsia
Propane G31
Fuch
-
sia
Fucsia
Electrical data
Voltage
V~
230
Frequency
Hz
50
Nominal Power consumption
W
78
Minimum Power consumption
W
57
Stand-by Power consumption
W
5
Protection degree
IPX5D
External fuse rating
A
3
Internal fuse rating
A
N° 2 - 2
AF
Flue design
Boiler type
B23P C13 C33 C43 C53 C63 C83
ø Coaxial
mm
60/100
ø Twin split pipes
mm
80/80
ø Roof
mm
80/125
Nominal heat flow rate
(A) (E)
kW
16,0
Exhaust temperature
(E)
°C
72,0
Mass flow rate
(E)
kg/s
0,0071
Flue gas figures
Nominal heat input
(A) (E)
kW
16,0
CO
2
content with gas G20
%
9,2-9,8
O
2
content with gas G20
%
3,9
CO content with gas G20
ppm
84,0
Exhaust temperature
(E)
°C
72,0
NOx class
5
Weighted NOx
ppm
17
(E)
Values refer tests with a 1 m flue working at the
nominal heat input
CO
2
contents
Nominal heat input
(A) (E)
kW
16,0
CO
2
content with gas G20 (range
min - max)
%
9,2-9,8
CO
2
content with gas G31 (range
min - max)
%
9,9-10,8
Minimum heat input
(A) (E)
kW
6,0
CO
2
content with gas G20 (range
min - max)
%
8,7-9,3
CO
2
content with gas G31 (range
min - max)
%
9,4-10,4
Other specifications
Height
mm
700
Width
mm
400
Depth
mm
290
Weight (dry)
kg
31,0
Water volume in the boiler (up to 1
bar)
l (kg)
2,0