- 66 -
INST
ALLA
TION
COMMISSIONING
•
Enter the ”programming mode” by pressing
keys
11
-
12
-
13
(Fig. 7.50) for 10 seconds
at the same time until the letters
Pr
that al-
ternate
with code
01
are displayed on the
LCD
display, indicating that ”parameter
01”
(Fig. 7.51) has been activated.
Fig. 7.50
11
12
13
Fig. 7.51
•
Press keys
11
and
13
(Fig. 7.50) at the
same
time until the value of parameter 06
(40
=
Advance Plus 16S ERP
or
41
=Ad-
vance Plus 25S ERP
or 42=Advance Plus
30S ERP)
is displayed on the LCD display
(Fig. 7.52).
Fig. 7.52
•
Press keys
11
and
12
(Fig. 7.50) at the
same
time to exit without changing the val
-
ue (return
to the parameters list Fig. 7.51)
.
•
Scroll the various parameters using keys
12
or
13
until the letters
Pr
that alternate with
code
02
are displayed on the LCD display,
indicating
that ”parameter 02” has been ac
-
tivated.
•
Repeat all the above setting sequences in
order to visualize the parameters and their
values.
•
Set the following parameter:
PARAMETER
LCD
VALUE
Pump speed
Pr 03
00
NTC on the c.h. return
Pr 18
00
LCD type
Pr 19
02
NTC inlet probe
Pr 29
00
•
Press keys
11
-
12
-
13
(Fig. 7.50) at the
same time for 10 seconds to exit the ”pro
-
gramming
mode”.