MENU 16 (PREVENTIVE ACTION)

Water treatment unit  

Water treatment unit decounter 

00000 

   

Decremented at every dispensing    

 

cycle requiring the supply of water. 

 

   

Entry data allowed: 0-65535 

Boiler  

   

Boiler decounter. Decremented at every

00000 

   

dispensing cycle requiring the supply  

 

of water. 

 

   

Entry data allowed: 0-65535 

HACCP Sanitization     

HACCP sanitization de-counter 

00000  

   

Decremented at every dispensing cycle  

 

requiring the supply of water. 

 

   

Entry data allowed: 0-65535 

Electro valves  

   

Electro valves decounter Decremented

00000 

   

at every dispensing cycle requiring the  

 

supply of water. 

 

   

Entry data allowed: 0-65535 

Seals  

   

Seals decounter Decremented every

00000  

   

time the group is closed. 

  

   

Entry data allowed: 0-65535 

Coffee grinders  

   

Coffee grinders decounter.  

00000  

   

Decremented every time the grinder is  

 

activated. 

 

   

Entry data allowed: 0-65535 

Coffee filters  

   

Coffee filters decounter. 

00000  

   

Decremented at every coffee dispensing  

 

cycle. Entry data allowed: 0-65535 

Coffee grounds reload 

Coffee grounds reload value. 

050  

   

Entry data allowed: 0-255 

Coffee grounds  

   

Coffee grounds decounter.

000 

   

Decremented at every coffee dispensing  

 

cycle.  Entry data allowed: 0-255 

MENU 17 (DECOUNTERS)

Decounters  

  The sub menus available for selection are as 

General param.  

  follows: 

 

  1. General parameters  (“General param. “) 

 

  2. Decounter value 

(“ Decount. Val. “) 

 

  3. Reserve  

 

(“ Reserve “) 

 

  4. Reload  

 

(“ Reload “) 

MENU 17.1 (GENERAL PARAMETERS) 

Enab. Decounters     Enables decounter management. 

No  

  Entry data allowed: No or Yes. 

Enable reset  

  Enables reset. 

No  

  Entry data allowed: No or Yes. 

Enable chip card     Enables chip card 

No  

  Entry data allowed: No or Yes. 

MENU 17.2 (DECOUNTER VALUES) 

Powder x decnt. 

  Instant powder × decounter value, where ×=1

00000  

  - max. number of instant powders. 

 

  Entry data allowed: 0-65535 

Decount. Beans  

  Beans decounter value. 

00000  

  Entry data allowed: 0-65535 

Decount. Cups 

  Cups decounter value. 

00000  

  Entry data allowed: 0-65535 

Sect. A×× decount.   Vega sector xx decounter value

00000 

  with xx=1-max. number of sectors. 

 

  Entry data allowed: 0-65535 

MENU 17.3 (RESERVE)

Enab.Powd.Res. 

  Enables instant powder decounter reserve 

No  

  management. 

 

  Entry data allowed: No or Yes. 

Enab.BeansRes. 

  Enables beans decounter reserve 

No 

  management. 

 

  Entry data allowed: No or Yes. 

Enab.CupRes. 

  Enables cup decounter reserve management. 

No  

  Entry data allowed: No or Yes. 

Enab.Sect.Res. 

  Enables sectors decounter reserve 

No 

  management.

 

  for Vega. Entry data allowed: No or Yes. 

Powders Reserv. ×    Instant powders x decounter reserve value

00000 

  with x=1-max. number of instant powders. 

 

  Entry data allowed: 0-65535 

Beans reserve  

  Beans decounter reserve value. 

00000  

  Entry data allowed: 0-65535 

CupsReserve 

  Cups decounter reserve value. 

00000  

  Entry data allowed: 0-65535 

Sect. A×× reserve    Vega sector xx decounter reserve value

00000 

  with xx=1-max. number of sectors. 

 

  Entry data allowed: 0-65535

MENU 17.4 (RECHARGE)

Enab.Powd.Rech.    Enables instant powder decounter recharge 

No  

  management. 

  

  Entry data allowed: No or Yes. 

Enab.BeansRech.    Enables beans decounter recharge 

No  

  management. 

 

  Entry data allowed: No or Yes. 

Enab.CupsRech. 

  Enables cups decounter recharge 

No  

  management. 

  

  Entry data allowed: No or Yes. 

Enab.Sect.Rech. 

  Enables sectors decounter recharge 

No  

  management for Vega. Entry data allowed: 

No or Yes. 

Powd. Recharge ×    Instant powders x decounter recharge value

00000 

  with x=1-max. number of instant powders. 

 

  Entry data allowed: 0-65535 

Beans recharge  

  Beans decounter recharge value. 

00000  

  Entry data allowed: 0-65535 

Cup Recharge  

  Cups decounter recharge value. 

00000  

  Entry data allowed: 0-65535 

Sect.A××Recharge    Vega sector xx decounter recharge value

00000 

  with xx=1-max. number of sectors. 

 

  Entry data allowed: 0-65535

MENU 18 (CLOCK)

Clock  

  The sub menus available for selection are as 

Set hours/minutes    follows: 

 

  1. Sets hours and minutes  

 

 

    (“Set hour/minutes“) 

 

      Visible only if the clock chip is provided. 

 

  2. Date  (“ Date “) 

 

      Visible only if the clock chip is provided. 

 

  3. Switch ON-switch OFF (“Switch on“) 

 

  4. Wash cycles (“ Wash cycles “) 

Summary of Contents for BVM 901 LEISA

Page 1: ...BVM 901 LEIsa CERT N 9191 BNVN UNI EN ISO 14001 2004 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...intended to come into contact with foodstuffs The tests have been made in accordance with the Harmonized European Standards 1 LOW VOLTAGE Electrical safety LV EN 60335 1 2002 A1 A11 Safety of Househol...

Page 4: ...ntribuisce ad evitare possibili effetti negativi sull ambiente e sulla salute e favorisce il riciclo dei materiali di cui composta l apparecchiatura Lo smaltimento abusivo del prodotto da parte dell u...

Page 5: ...ined as the person responsible for the installation of the automatic distri butor the starting up operations and the function settings Each regulation operation is the exclusive responsibility of the...

Page 6: ...2 SPANNERS fork type n 7 n 8 n 10 n 12 n 14 SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Teflon small size for Trimmer regula tion RATCHET SPANNE...

Page 7: ...manual is an integral part of the equipment and as such must always remain inside of the same so as to allow further consultations on the part of the various operators until the dismantlement and or...

Page 8: ...or belongings in consequence to Incorrect installation Inappropriate electrical and or water connection Inadequate cleaning and maintenance Not authorized modifications Improper use of the distributor...

Page 9: ...kW to 2 5 kW Nominal current 7 42 A AVERAGE CONSUMPTIONS Water supply connection 3 4 gas Electrical supply connec Schuko plug WATER SUPPLY from main supply with pressure between 0 5 and 6 5 bar BOILE...

Page 10: ...ee group and grinder 2 Container units for soluble drinks 3 Coffee bean container 4 Coin mechanism 5 Switching 6 Cup holder 7 Instant boiler 8 Dispensing chamber 9 Keyboard 10 Master board 11 Coffee g...

Page 11: ...or the dispensing of drinks pre pared mixing food substances with water by infusion as far as concerns coffee For this purpose use products declared as suitable by the manu facturer for automatic dist...

Page 12: ...e user shall therefore independently see to obtaining them via the appropriate dispenser available in the vicinity of the vending machine and shall ensure that they are correctly positioned in the dis...

Page 13: ...pump that dispenses the quantity of programmed water is activated and is controlled by an appropriate electronic device volumetric counter The instant product geared motor activates the helicoidal scr...

Page 14: ...eared motor brings it into the dispensing position and simultaneously compresses the ground coffee Fig 3 12 the pump that dispenses the quantity of programmed water and that is controlled by a specifi...

Page 15: ...rene packaging Fig 4 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environment On the package labels are a...

Page 16: ...butor and remove the adhesive tape from the components listed here below coin mechanism cover keyboard cards product containers The packing material must not be left accessible to others as it is a po...

Page 17: ...e or belongings in consequence to Incorrect installation Inappropriate electrical and or water connection Inadequate cleaning and maintenance Not authorized modifications Improper use of the distribut...

Page 18: ...e from the water mains should it be found to be necessary Fig 6 3 before making water connections make some water flow out of the tap so as to eliminate possible traces of impurities and dirt Fig 6 4...

Page 19: ...upply cable of H05VV F 3x1 mm with SCHUKO plug Fig 6 8 The sockets that are not compatible with that of the machine must be replaced Fig 6 9 The use of extension adapters and or multiple plugs is forb...

Page 20: ...tributor is started up the airbreak is filled with wa ter When the floater is in the upper position the machine will start loading water automatically and this will go on until 300cc of water are coun...

Page 21: ...nds carefully prepare an anti bacterial cleaning solution with a chlorine base products that can be purchased in pharmacies following the concentrations given on the product instruction labels Before...

Page 22: ...18 the parts must soak in the solution for the time indicated on the solutions instruction label Recover all the parts rinse them abundantly dry them perfectly and proceed with the re assembly in the...

Page 23: ...S so as to ve rify setting of the parameters that must be coherent with the system used 6 7 Product container loading with machine off 6 7 1 Loading containers Filling is possible keeping the containe...

Page 24: ...d 13 to 24 according to the following table Key number BVM901 DP1 Key 1 DP1 Key 2 DP1 Key 3 Selection 13 DP1 Key 4 Selection 14 DP1 Key 5 Selection 15 DP1 Key 6 Selection 16 DP1 Key 7 Selection 17 DP1...

Page 25: ...s pw will access all the menu items that are worth programming and as actually needed Programmable parameter 2 Limited menu programming password this pw will access only the items enabled via the redu...

Page 26: ...only 3 4 of the instant powder dose for a total of 3s 3 Generally speaking the first 4 bar grids each correspond to of the instant powder dose whilst the second 4 bar grids each correspond to 1 4 of...

Page 27: ...presso sugar 00 0 s function With P going from P1 to P24 The entry data allowed here is 0 0 to 25 5 s Ev Nr P Sets the electro valve number 0 With P going from P1 to P24 stands for the order of the el...

Page 28: ...depends on the decimal point MENU 10 3 BANKNOTES LINE Banknote xx Sets the value to be associated with 000 00 banknote xx Where xx 1 to 16 The entry data allowed here is 0 to 65535 and display depend...

Page 29: ...data allowed 0 65535 Sect A decount Vega sector xx decounter value 00000 with xx 1 max number of sectors Entry data allowed 0 65535 MENU 17 3 RESERVE Enab Powd Res Enables instant powder decounter res...

Page 30: ...switch off time slot functions based on activation of the ma chine s switch off parameter that can be set via the windows program If the start value is bigger or equal to the end value the time slot i...

Page 31: ...n The following message comes up on display in line 1 Test run complete ONLY WATER TEST This function allows the operator to run test selections of the possible drinks available without the powders be...

Page 32: ...t s On application of the HACCP certain hygienic regulations are laid down for company self checking procedures concerning Cleaning of the premises Product transportation Machinery maintenance Waste d...

Page 33: ...can be removed from its housing to make the task easier Fig 9 6 empty the waste liquids bin clean it and or substitute it Fig 9 7 substitute the coffee spent grounds container coffee in beans versions...

Page 34: ...dge of the equipment is necessary Monthly effect the debacterisation of all the parts in contact with food substances using chlorine based solutions following the operations already described under ch...

Page 35: ...cone grease for alimentary use Fig 9 12 lower filter piston 1 connecting bar 2 piston guide 3 Every 10000 vends we advise to substitute the gaskets and the filters gaskets Loosen the screw Fig 9 13 wa...

Page 36: ...must be carried out in order to assess the efficiency of the regulation the finer the granules the greater the time required for product delivery 9 3 2 Regulation of the instant solenoid water deliver...

Page 37: ...divided by the payment system s basic currency amounts to more than 250 The alarm is auto resetting and it will therefore disappear as soon as the price that is higher than the test parameter is repro...

Page 38: ...null The alarm warning is auto resetting therefore it will reset itself immediately as soon as the decounter value is programmed Electro valves Electro valve decounter not blocking warning Occurs if t...

Page 39: ...blematiche utilizzare il presente modulo per segnalare alla Bianchi la problematica e richiedere pezzi di ricambio in garanzia Si fa notare che la spedizione di questo modulo compilato la condizione p...

Page 40: ......

Page 41: ...ole Motori Elettromagneti Indirizzo e mail N ro Fax per conferma attivazione garanzia DA INVIARE FAX 39 035 883304 o e mail customercare bianchivending com Matricola N tel Cliente SCHEDA RICHIESTA RIC...

Page 42: ......

Page 43: ......

Page 44: ......

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ......

Page 49: ......

Page 50: ...Cod 11116621 Ediz 10 2009...

Reviews: