background image

Equipment list

Below is the list of Biamp Vocia equipment used in this project:

• 5 - Vocia

DS-4

• 2 - Vocia

DS-10

• 2 - Vocia

EWS-10

• 2 -

VA-8150CV

• 2 -

VA-4300CV

• 1 -

VA-8600

• 4 - WR-1

• 1 - VI-6

• 3 - ANC-1

• 1 - LSI-16e

• 1 - CI-1

• 1 - MS-1e

• 8 - PLD-1*

• 23 - PLD-2*

4-button desktop paging station, cardioid microphone, PoE, CobraNet audio/control

10-button desktop paging station, cardioid microphone, PoE, CobraNet audio/control

10-button emergency wall-mount paging station, cardioid microphone, PoE, CobraNet audio/control

8-channel x 150W constant voltage 70V/100V amplifier, CobraNet audio/control

4-channel x 300W constant voltage 70V/100V amplifier, CobraNet audio/control

8-channel x 600W (2400W Total) constant voltage 70V/100V amplifier, CobraNet audio/control

Wall remote for background music source selection and volume control

6-channel networked audio input expansion device, 4 line-level inputs, 2 mic/line inputs with
phantom power, PoE, CobraNet audio/control

Provides automatic output level adjustments in response to changes in ambient noise levels, PoE,
CobraNet audio/control

Enhanced emergency interface between the Vocia paging system and the emergency/fire alarm
systems

Control interface for LSI-16e

Message Processor for recorded announcements & scheduling

Speaker line monitoring device for Vocia Amplifiers (VA-8600)

Speaker line monitoring device for Vocia Amplifiers (VA-8150CV and VA-4300CV)

*Optional - Active and passive speaker line monitoring devices are available in the Vocia product line and may be
required for VACIE and evacuation compliance. Biamp recommends speaker line monitoring be used with all life-safety
and emergency systems however these units are not shown or included in the system diagram above. Please check
with authorities if speaker line monitoring is required in the local jurisdiction.

Note that other non-Biamp equipment is required in addition to this list, including the loudspeakers, ambient sensing
microphones, media sources, and CobraNet PoE network switches.

Vocia configuration file

A complete Vocia configuration file is available for download here:

Copyright 2013-2020 Biamp Systems

http://support.biamp.com/

2

Summary of Contents for Vocia ANC-1

Page 1: ...gency it s critical structured clear to follow evacuation directions are given Vocia is capable of meeting and exceeding that requirement Paging system design Paging System Functionality Scope 7 Paging Stations to provide live pages from the Bar Bridge Casino Pool Restaurant Security and Theater 2 Emergency Paging Stations to provide live paging from the Bridge Helm and Security room 10 Regular Pa...

Page 2: ...djustments in response to changes in ambient noise levels PoE CobraNet audio control Enhanced emergency interface between the Vocia paging system and the emergency fire alarm systems Control interface for LSI 16e Message Processor for recorded announcements scheduling Speaker line monitoring device for Vocia Amplifiers VA 8600 Speaker line monitoring device for Vocia Amplifiers VA 8150CV and VA 43...

Page 3: ...ovide a better understanding on the most essential settings inside the software the Zones and Page Code assignment can be previewed below Zones Configuration Pages Codes Emerge Emergency Messages Amplifier Zone Assignment Lower Deck VA 4300CV LSI 16 Em Copyright 2013 2020 Biamp Systems http support biamp com 3 ...

Page 4: ...ecreases as guests move between different areas ANC 1 s have been installed in the restaurant and casino to automatically adjust BGM and paging levels to account for this Zone assignment ten Zones one for each main section of the ship during non emergency operation Additional two paging Zones to all of the upper deck and all of lower deck available Emergency Zone assignment Upon detection of an al...

Page 5: ... The message processor MS 1e is used for hosting non emergency recorded messages and scheduled announcements of daily activities External connections to the system Fire panel connection to the LSI 16e The functionality of the LSI 16e has been tailored to the specific requirements in the EN 54 16 European life safety standard However the LSI 16e and CI 1 are still applicable in installations that r...

Page 6: ... but leaves the system in emergency mode Physical Input 16 returns the system to regular non emergency mode Please refer to the picture on the right or review the full LSI 16e connection documentation here Speaker lines Speaker circuits are being installed as constant voltage speaker lines 70V or 100V can be selected via software In this example all speaker circuits are 70V Select speaker transfor...

Page 7: ...efault to unity gain This allows the system to start working once the file is loaded with minimal adjustments Select the output voltage on the amplifiers to 70V or 100V as needed Adjust the amplifier output level as needed for each zone While at the amplifier s properties go to ELD Assignment tab and assign PLD s if being used Adjust ambient sense microphones input levels and values Check and conf...

Page 8: ...Further reading Vocia Network Communications CI 1 Wiring Guide LSI 16 setup and wiring guide Constant voltage speaker systems Copyright 2013 2020 Biamp Systems http support biamp com 8 ...

Reviews: