Networking details
Vocia supports two modes of
depending on the network topology. One
requires a direct connection to a CobraNet network while
the other requires an IP-based connection to the MS-1e
Message Processor to access the system. The factory
default IP address for the MS-1e is 192.168.1.101, which
is already set up in the example configuration accordingly.
Should any problems occur to connect to the system, use
the MS-1e device maintenance tool in Vocia Software.
Setup Requirements:
The following devices will require 802.3af (Class 3) power from a PoE capable switch or a suitable PoE injector:
• 5 - Vocia DS-4
• 2 - Vocia DS-10
• 2 - Vocia EWS-10
• 4 - WR-1
• 1 - VI-6
• 3 - ANC-1
• 1 - LSI-16e (2 Ports)
System setup
All Vocia devices are set, by default, to unity gain. This allows the system to start working, once the file is loaded, with
minimal adjustments.
• Select the output voltage on the amplifiers to 70V or 100V as needed
• Adjust the amplifier
as needed for each zone
• While at the amplifier's properties, go to "ELD Assignment" tab and assign PLD's if being used
• Adjust ambient sense microphones input levels and values
• Check and confirm adequate DS-10, DS-4 and EWS-4 microphone input level from the
tab
found under the respective units properties
• Verify there are no Alarms or Faults active in the LSI-16e. If present, verify
• Upload and assign emergency messages that have been customized to the ships evacuation requirements
• Adjust scheduled announcements of daily activities
• Test the Emergency Evacuation Systems with each of the triggers for proper functionality and validation