• In this design, all paging stations have the capability to page their respective Zones and the security office, at
minimum
• The higher the number in the Priority field the more precedence is given to the Page.
• Six channels of background music are available for selection. Inputs are via the VI-6 (6 channel mic/line input
device). All sources are selectable and level controllable from the WR-1 wall remotes for the Restaurant, Bar, Pool
and Casino areas.
• Ambient noise increases or decreases as guests move between different areas. ANC-1's have been installed in the
restaurant and casino to automatically adjust BGM and paging levels to account for this.
• Zone assignment - ten Zones, one for each main section of the ship during non-emergency operation. Additional
two paging Zones to all of the upper deck, and all of lower deck available.
• Emergency Zone assignment - Upon detection of an alarm, Vocia enters emergency mode and the vessel is
automatically re-zoned to 8 emergency zones. The lower emergency areas are delayed by 20 seconds to allow the
upper deck time to begin an evacuation without congestion.