ENGLISH
INSTALLATION MANUAL
ACCESS MENUS Fig. 1
stat
- +
OK
vers
bft . . .
+
/
-
OK
0000
+
/
-
n. cycles
OK
01.33
- +
err
02.01
........
30.15
+
/
-
Exit Menù
Confirm/Switch on display
Scroll up
Scroll down
See PARAMETERS MENU
See LOGIC MENU
language
List of last 30 errors
Control unit software version
No total
manoeuvres (in hundreds)
LIMIT SWITCH
ADJUSTMENT
l.sw adj
autoset
ALT
follow the user guide
x2
0---
10--
150-
1520
ok
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
***
password
0---
10--
150-
1520
prg
Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT
PHOT photocell input activated
PHOP
PHOT OP opening photocell input activated
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
SWC
SWC motor closing limit switch input activated
SWO
SWO motor opening limit switch input activated
rls
Mechanical release activated
Check position of release
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or param-
eter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or param-
eter/logic setting
er06
8k2 safety edge test failed
Check safety edge connection and/or
parameter/logic settings
ER1x
*
Board hardware test error
- Check connections to motor
- Hardware problems with board (contact
technical assistance)
ER2x
*
Encoder error
- Motor power cables disconnected.
Reverse 2 phases in the supply terminal.
- Actuator movement is too slow or stopped
with respect to programmed operation.
ER3x
*
Reverse due to obstacle - Amperostop
Check for obstacles in path
ER4x
*
Thermal cutout
Allow automated device to cool
ER70, ER71
ER74, ER75
Internal system supervision control error.
Try switching the board off and back on again.
If the problem persists, contact the technical
assistance department.
ER72
Consistency error of the control unit’s parameters (Logics
and Parameters)
Pressing OK the detected settings are confir-
med. The board will keep on working with the
detected settings.
The board settings must be checked (Para-
meters and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on working
with D-track as a default.
An autoset is required
*
X
= 0, 1, .., 9, A, B, C, D, E, F
35.40
Obstacle threshold
Instantaneous force motor
LEO B CBB 3 400 W 01-
13