ENGLISH
INSTALLATION MANUAL
Logic
Definition
Default
Cross
out
setting
used
Optional extras
HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
3
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
Input 65 is configured as CLOSE UP.
WARNING: safety devices are not enabled during closing.
IBL OPEN
Block pulses during
opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (See Fig.D1).
1
Opens in other direction to standard operating mode (See Fig.D1).
SAFE 1
Configuration of
safety input SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
SAFE 3
Configuration of
safety input SAFE 3.
77
2
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
IC 1
Configuration of
command input IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
IC 2
Configuration of
command input IC 2.
62
4
2
Input configured as Open.
3
Input configured as Close.
IC 3
Configuration of
command input IC 3.
64
2
4
Input configured as Ped.
5
Input configured as Timer.
IC 4
Configuration of
command input IC 4.
65
3
6
Input configured as Timer Pedestrian.
Protection
level
Setting the
protection level
0
0
A -
The password is not required to access the programming menus
E -
The board’s parameters can be edited via the U-link network
1
Not used
2
Not used
3
Not used
4
A -
You are prompted to enter the password to access the programming menus
The default password is 1234.
E -
The option of editing the board’s parameters via the U-link network is disabled.
SERIAL MODE
Serial mode
(Identifies how board
is configured in a BFT
network connection).
0
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
ADDRESS
Address
0
[ ___ ]
Identifies board address from 0 to
119
in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
LEO B CBB 3 400 W 01-
17
D811849 00100_04