FEATURES
AR
SR
AC
SC
I
ND
I
NDUSTRI
AL
AUTOMATI
C
CLOSI
NG
TI
MER
x
x
x
x
UNI
NTERRUPTED
OPEN
CYCLE
x
x
I
NSTANT
REVERSE
ON
CLOSI
NG
x
x
HOLD
TO
RUN
x
QUI
CK
REMOTE
PROGRAMMI
NG
x
x
x
x
AUTOMATI
C
RESI
DENTI
AL
SEMI
-AUTOMATI
C
RESI
DENTI
AL
AUTOMATI
C
COMMERCI
AL
SEMI
-AUTOMATI
C
COMMERCI
AL
PRE-
ALARM
QUI
CK
SETUP
MENU
Automatic Closing Timer:
Automatically closes the gate after gate fully opens and all safety devices
are cleared.
Pre-Alarm:
Energizes auxiliary relay with value set to “6”, for 3 seconds before energizing the
motors.
Uninterrupted Open Cycle:
Remote controls and START input is ignored during the open cycle.
Instant Reverse On Closing:
A START command will instantly re-open gates during the close cycle.
Otherwise, a START command first stops the gate requiring a second command to re-open.
Hold-To-Run:
START command is disabled. Gate requires a constant “open “ or “close” command for
it to run.
Quick Remote Programming:
Allows adding remotes wirelessly using an existing working
transmitter.
PRESETS
The “Residential” presets are not exclusive for residential applications the same way
“Commercial” presets are not exclusive for commercial applications. They can both be
used on any application depending on the needs and preferences of such installation.
You can further customize your settings by using the Main Programming Menu.