£IA
Control unit
00: disabled
UP
UPS
0
/: enabled, opens automatically during mains failure
02: enabled, closes automatically during mains failure
AWARNING:THIS
SELECTION MAY BE DANGEROUS
[r
Deceleration torque (not avail-
20-B0
able for hydraulic bollards)
Sf:
Exiting the menu/saving
Pressing the"F"key exits the programming menu and changes are saved
Description of level 2 parameters
•Sr: Request for maintenance
- 00: the request for maintenance is not active.
00
so
-
0
/: after the programmed cycles set by the counters nt and nl, the programmed output is activated (see parameters o'-1, □S)
- 02: after the programmed cycles set by the counters nt and nl, the programmed output is activated (see parameters o'-1, □S) and
the bollard lights flash twice.
• nl:-nl: Programming maintenance cycles in thousands and millions
These two parameters set the number of cycles after which a request for maintenance is signalled.
Thousands of cycles can be set with the nt parameter, millions of cycles with the nl parameter. Example: to set maintenance alarm
after 275 000 cycles, set nl to 0.2 and nt to 15.
•
F
[: Closing limit switch presence.
This parameter must be set only for bollards with additional limit switch installed for closed-fully up position. After every default
operation it is set to
0 I
for H2 and
GR
bollards,
00
for the others.
• oY= I I: oS= I I: Assistance required
If configured, the contact indicates that the electronic control unit detected an error in the automation and in particular, the failure
of the travel stop or the solenoid valve (hydraulic bollards only). The error is also signalled by the triple flashing of the cover lights, if
installed
. /: E:
TERMON (integrated electronic motor heating system)
Should be activated ONLY when the ambient temperature where the bollard is installed drops below a minimum of 0
°
c for all the
day.
tE
= 00, TERMON is disabled (default)
tE
=
0 I,
minimum heating
tE
=
30,
maximum heating
•
[
r: Deceleration torque (electromechanical bollards only)
Sets the deceleration speed at the end of the closing manoeuvre.
The value of the deceleration speed at the end of opening is factory preset and cannot be modified.
8.4
3rd LEVEL
PROGRAMMING
The following table gives the 3rd level functions and the adjustable parameters.
�=DEFAULT value set in factory.
ti\=
parameter value set during installation: should be filled if
DEFAULT value is modified.
Par.
Function
Settable data
�
ti\
Pd
PDM dynamic input polarity
00: input N.O.
00
0
/: input N.C.
Lf:
Limit switch connection
00: series (N.O. 2-wire sensors)
00
0
/: parallel (N.C. 3-wire sensors)
pp
Pressure switch polarity (for
00: N.O. (used until
2012)
01
hydraulic bollards only)
O
/: N.C. (used from
2013)
PE
00: N.O.
00
ECD Pressure switch polarity
0
/: N.C.
PR
00: N.O.
00
Input AUX polarity
0
I: N.C.
PY
Output 4 polarity
00: N.O.
00
PS
Output 5 polarity
0
/: N.C.
[P
Commands accepted during pause 00: OFF
01
time
0
/: ON
- 32 -