13.2
INSTALLATION B
AUTOMATIC ENTRY OR EXIT
This solution is recommended when you want to allow entry to a reserved area, without using any commands, allowing transit of vehicles in
just one direction.
The vehicle approaches the
reserved area. When over the
loop
51,
the bollard goes down.
When the vehicle is no longer
over loop 52, the bollard will
rise again.
Loops S1 and S2 also have a safety function in thatthey will not let the bollard to move all the time if the vehide is over S1 or S2.
RECOMMENDED DIMENSIONS
- Connect the
N.O.
contact of the coil receiver
51
to the
OPEN
input.
- Connect the
N.O.
contact of the 52 loop receiver to the
CLOSE
input.
- The dimensional values given are only approximate.
*
We suggest installing the
"RME 2"
metal mass detector.
PARAMETER
DATA
DESCRIP TION
[L
02
The close command acts as a close-when-released and safety function.
n,
' I
00
Radio channel 1: Disabled
CJ
FP
01
II
Opening consent
LO
01
Semiautomatic logic
[P
00
Command during pause is OFF