Control unit
m
13. EXAMPLES OF CONTROLLED ENTRIES/EXITS
13.1
INSTALLATION A
CONTROLLED ENTRY OR EXIT
This solution is recommended when you want to enter a reserved area in just one direction, by activating a command (radio control, proximity
key, magnetic keys, etc.).
The vehicle approaches the
reserved area.
When the vehicle is on the loop S 1
the bollard will go down only after
a command (ex.: remote control).
--:
If the bollard is closing and the
user wants to lower it again, the
vehicle must be over loop
S1
and
the command must be repeated.
�
-<.....:.. ______ _
When the vehicle is no longer
over loop
S2
the bollard will
close.
======���=====
Sl
::======
Loops S1 and S2 also have a safety function in thatthey will not let the bollard to move all the time if the vehide is over S1 or S2.
RECOMMENDED DIMENSIONS
- Connect the
N.O.
contact of the
S1
loop receiver to
PDM
input.
- Connect the
N.O.
contact of the
S2
loop receiver to
CLOSE
input.
- The dimensional values given are approximate.
*
We suggest installing the
"RME 2"
metal mass loop detector.
PARAMETER
DATA
DESCRIPTION
[l
02
The close command acts as a close-when-release and safety function.
n.,
,. I
02
Radio channel 1: Open
CJ
FP
01
II
Opening consent
LO
01
Semiautomatic logic
[P
DO
Commands during pause is OFF
- 37 -