12
-
ALTAIR-P - Ver. 03
D81
1506_03
INSTALLATION MANUAL
ENGLISh
programmer
, carefully read the instructions relating to
universal palmtop
programmer
, and proceed in the following way.
Connect the
universal palmtop programmer
to the control unit through the
UNIFLAT accessory (See fig. 4). Enter the “CONTROL UNITS” menu, and the
“PARAMETERS” submenu, then scroll the display screenfuls using the up/
down arrows, and set the numerical values of the parameters listed below.
For the function logics, refer to the “LOGIC” submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the “configuration” paragraph.
6) CONFIGURATION
The display programmer is used to set all the
ALTAIR-P
control panel
functions.
The programmer is provided with three pushbuttons for menu scrolling and
function parameter configurations (Fig. 2):
+ menu scrolling/value increment key
- menu scrolling/value reduction key
OK Enter (confirm) key
The simultaneous pressure of the + and – keys is used to exit the active
menu and move to the preceding menu.
If the + and – keys are pressed simultaneously at the main menu level (param-
eters, logics, radio, language, default), programming is exited and the display
is switched off (the END message is displayed).
The modifications made are only set if the OK key is subsequently pressed.
When the OK key is pressed for the first time, the programming mode is
entered.
The following pieces of information appear on the display at first:
- Control unit Software version
- Number of total manoeuvres carried out (the value is expressed in
thousands, therefore the display constantly shows 0000 during the first
thousand manoeuvres)
- Number of manoeuvres carried out since the latest maintenance opera-
tion (the value is expressed in thousands, therefore the display constantly
shows 0000 during the first thousand manoeuvres)
- Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first
menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus available.
The predefined parameter is shown between square brackets
[ 0 ]
.
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
6.1) PARAMETERS MENU
- Operation time (
vork. t
) [010.0s]
Set the numerical value of the operation time from 3 to 180 seconds.
- Pedestrian operation time
(
ped. t
)
[006.0s]
Set the numerical value of the control panel operation time from 3 to 90
seconds.
- Automatic Closing Time (
TCA
) [ 010.0s ]
Set the numerical value of the automatic closing time from 3 to 120 seconds.
WARNING: Check that the impact force value measured at
the points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
- Opening delay time (
open delay time
) [ 001.0s ]
Set the opening delay time between 1 and 10 seconds.
- Closing delay time (
cls delay time
) [ 001.0s ]
Set the closing delay time between 1 and 60 seconds.
- Motor torque (
mot torque
) [ 050% ]
Set the numerical value of the motor torque between 1% and 99%.
- Zone (
zone
) [ 0 ]
Set the zone number between a minimum value of 0 and a maximum
value of 127. See paragraph 8 on “Serial connection”.
6.2) LOGICS MENU
- TCA (
TCA
) [ OFF ]
ON: Activates automatic closing
OFF: Excludes automatic closing
- 3 Steps (
3 step
) [ OFF ]
ON: Enables 3-step logic. A start impulse has the following effects:
door closed: ...............................................................................opens
on opening: ..............................stops and enters TCA (if configured)
door open: ................................................................................. closes
on closing: ............................................stops and reverses movement
after stopping: ............................................................................opens
OFF: Disables 3-step logic.
- Impulse lock (
ibl open
) [ OFF ]
ON: Enables impulse lock during the opening phase.
OFF: Excludes impulse lock during the opening phase.
- Pre alarm (
pre-alarm
) [ OFF ]
ON: The blinker comes on about 3 seconds before the motor starts.
OFF: The blinker comes on at the same time as the motor starts.
- Rapid closing (
fast cls.
) [ OFF ]
ON: Closes the gate after photocell disengagement, before waiting for the
end of the TCA (automatic closing time) set.
OFF: Command not entered.
- Photocells on opening (
photoc. open
) [ OFF ]
ON: In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the
motion only after the photocell is disengaged.
- Gate-open or 2nd radio channel warning light (
sca 2ch
) [ OFF ]
ON: The output between terminals 15 and 16s configured as Gate-open
warning light, in this case the 2nd radio channel controls pedestrian
opening.
OFF: The output between terminals 15 and 16 is configured as 2nd radio
channel.
- Motors in operation (
1 mot. ON
) [ OFF ]
ON: Only motor 2 is in operation (terminals 7, 8 and 9).
With this configuration, the pedestrian input is disabled.
OFF: Both motors are in operation.
- Ram blow on opening (
ram blow c. op
) [OFF]
ON: Before opening, the gate is pushed for about 2 seconds in the closing
direction. This allows the electric lock to be released more easily (not
affected by limit switches).
OFF: Excludes the ram blow.
IMPORTANT –
When no adequate mechanical backstops are fitted,
do not use this function.
- Fixed code (
fixed code
) [ OFF ]
ON: The receiver is configured for operation in fixed-code mode, see pa-
ragraph on “Radio Transmitter Cloning”.
OFF: The receiver is configured for operation in rolling-code mode, see
paragraph on “Radio Transmitter Cloning”.
- Radio transmitter programming (
radio prog
) [ ON ]
ON: This enables transmitter storage via radio:
1 - First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 - Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new tran-
smitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio
menu.
- Master/Slave (
Master
) [ OFF ]
ON: The control panel is set as Master in a centralised connection (see
Paragraph 8).
OFF: The control panel is set as Slave in a centralised connection (see
Paragraph 8).
- Start-Open
selection (
start-open
) [ OFF ]
ON: The input between the two terminals 17-20 acts as open.
OFF: The input between the two terminals 17-20 acts as start.
- PED-CLOSE selection (
ped-close
) [ OFF ]
ON: The input between the two terminals 17-21 works as CLOSE.
OFF: The input between the two terminals 17-21 works as PEDESTRIAN.
6.3) Radio Menu (
radio
)
- Add (
add
)
Allows you to add one key of a radio control device to the receiver memory;
after storage it displays a message showing the transmitter number in the
memory location (from 01 to 64).
NOTE:
When using transmitters with two or more channels, the first
push-button which has been stored is associated to the START function.
If a second push-button is stored, it will be associated to the pedestrian
function.
- Read (
read
)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the key
number (T1, T2, T3 or T4).
- Delete (
erase 1
)
Removes one single key of a transmitter from the receiver memory; after
deletion it displays a message showing the receiver number in the memory
location (from 01 to 64).
- Eliminate list (
erase 64
)
WARNING!
Completely removes all memorised radio control devices from
the receiver memory.
Summary of Contents for ALTAIR-P
Page 2: ... ALTAIR P Ver 03 D811506_03 ...
Page 39: ...ALTAIR P Ver 03 39 D811506_03 ...
Page 40: ......