INSTALLATION MANUAL

1) GENERAL INFORMATION

The 

ALCOR AC A

 control panel comes with standard factory settings. 

Any change must be set by means of the TRIMMER and DIP SWITCH settings. 

Its main features are:   

-  Checking of 2 single phase motors 

-  Separate inputs for safeties

-  Rolling-code in-built radio receiver.

The board has a terminal strip of the removable kind to make maintenance or re-

placement easier. It comes with a series of prewired jumpers to make the installer’s 

job on site easier. 

The jumpers concern terminals: 70-71, 70-72, 70-74. If the 

above-mentioned terminals are being used, remove the relevant jumpers.

TESTING

The 

ALCOR  AC  A

  panel  controls  (checks)  the  start  relays  and  safety  devices 

(photocells) before performing each opening and closing cycle. 

If  there  is  a  malfunction,  make  sure  that  the  connected  devices  are  working 

properly and check the wiring.

2) TECHNICAL SPECIFICATIONS

 

Power supply

110-120V 50/60Hz
220-230V 50/60 Hz

Panel dimensions

Fig. F

Low voltage/mains insulation

> 2MOhm 500V 

Operating temperature range

-20 / +50°C

Dielectric rigidity

mains/LV 3750V~ for 1 minute

Accessories power supply

4V~  (demand max. 0,2A) 

AUX 0 - Flashing

Contact powered

120V~ 40W max
230V~ 40W max

Fuses

Fig. C

Built-in Rolling-Code 

radio-receiver

frequency 433.92MHz

Setting of parameters and logics T DIP SWITCH
Max.  n°  of  remotes  that  can  be 

memorized

63

Maximum power

750W

Maximum work time

90s

Usable transmitter versions:

All ROLLING CODE transmitters compatible with

.

3) TUBE ARRANGEMENT Fig. A

Install the electrical system referring to the standards in force for electrical systems 

CEI 64-8, IEC 364, harmonization document HD 384 and other national standards. 

4) TERMINAL BOARD WIRING Fig. C

For  the  electric  diagram  and  the  cross  section  of  the  cables  refer  to  the 

manual of the actuator.

Once suitable electric cables have been run through the raceways and the auto-

mated device’s various components have been fastened at the predetermined 

points, the next step is to connect them as directed and illustrated in the diagrams 

contained in the relevant instruction manuals. Connect the live, neutral and earth 

wire (compulsory). 

WARNINGS -

 When performing wiring and installation, refer to the standards 

in force and, whatever the case, apply good practice principles. Wires carrying 

di

ff

erent voltages must be kept physically separate from each other, or they must 

be suitably insulated with at least 1mm of additional insulation. 

Wires must be secured with additional fastening near the terminals, using devi-

ces such as cable clamps. All connecting cables must be kept far enough away 

from dissipaters.

WARNING! For connection to the mains power supply, use a multicore cable 

with a cross-sectional area of at least 3x1.5mm

2

 of the kind provided for by 

the regulations in force. 

To connect the motors, use a cable with a cross-sectional area of at least 

1.5mm

2

 of the kind provided for by the regulations in force. 

The cable must be type H05RN-F at least.

5) SAFETY DEVICES

Note: only use receiving safety devices with free changeover contact.

5.1) TESTED DEVICES Fig.G

5.2

)

 CONNECTION OF 1 PAIR OF NON

-

TESTED PHOTOCELLS FIG. B

 

WARNING!

The values of the impact force according to EN 12453 are only observed with 

the use of safety edges (active) connected to the board.

6

)

 MEMORIZING TRANSMITTERS FIG. D

7) REVERSING THE OPENING DIRECTION (Fig.E)

8

)

 ADJUSTMENT PROCEDURE

-

  Before turning the unit on, check electrical connections.

-  Set the following parameters: 

  Automatic Closing Time, 

  Phase shift timing while closing

-  Set the logics.

WARNING! Incorrect settings can result in damage to property and injury 

to people and animals. 

WARNING: Check that the force of impact measured at the points pro-

vided for by standard EN 12445 is lower than the value laid down by 

standard EN 12453.

KEYS

KEYS

Description

S1

Add Start Key

associates the desired key with the Start command.

S2

Add Pedestrian Key

associates the desired key with the pedestrian command.

S2

>5s

Con

fi

rms the changes made to parameter settings and operating 

S1+S2

>10s

Erase List

WARNING! 

Erases  all  memorized  transmitters  from  the 

receiver’s memory.

LED INDICATORS:

POWER

Steadily lit: - Mains power on - Board powered - Fuses intact

START

Lit: START input activated

OPEN

Lit: OPEN pedestrian input activated

STOP

Unlit: STOP input activated

PHOT

Unlit: PHOT photocell input activated 

FAULT 1

PHOT input safety device test input diagnostics

BAR

Unlit: BAR safety edge input activated

FAULT 2

BAR input safety device test input diagnostics

ERR

Unlit: no error
LIT: see error diagnostics table

RADIO

(GREEN)

Unlit: remote programming not active

Radio LED only 

fl

ashing: Remote programming active, waiting for 

hidden key.

Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated

SET

Lit: see error diagnostics table
Flashing in sync with Radio LED: Transmitter deletion in progress

TABLE ERR

Led ERR

Lit

slow  

fl

ashing

fast  

fl

ashing

Led SE

T

Unlit

Photocell test, 

Costa o Costa 8k2 

failed

 

 

- Check photocell 

connection and/

or logic settings

Lit

Reverse due to 

obstacle - Ampe-

rostop 

 

- Check for obsta-

cles in path

slow  

fl

ashing

Test hardware 

card error
- Check the 

connection to the 

motor

- Hardware pro-

blems to the card 

(contact technical 

assistance)

Changed  settings 

and/or  Operating 

logics press S2 for 

5s to con

fi

rm.

8  -

  ALCOR AC A

D814011 00100_02

Summary of Contents for ALCOR AC A

Page 1: ...UADRO DE MANDOS BEDIENINGSPANEEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen aan de binnenkant zorgvuldig D814011...

Page 2: ...xion d une paire de photocellules non vérifiées pour les photocellules vérifiées consultez les pages suivantes Anschluss von einem Paar nicht überprüfter Fotozellen für überprüfte Fotozelle siehe die folgenden Seiten Conexión de 1 par de fotocélulas no comprobadas para fotocélulas comproabdas véanse las siguientes páginas Aansluiting van 1 paar niet geverifieerde fotocellen Raadpleeg de volgende p...

Page 3: ...hen an Fijo Continu Lampeggio continuo Continuous flashing Clignotement continu Kontinuierliches Blinken Parpadeo continuo Continu knipperen MEMORIZZAZIONE RADIOCOMANDO MEMORIZING REMOTE CONTROLS MÉMORISATION RADIOCOMMANDE ABSPEICHERUNG DER FERNBEDIENUNG MEMORIZACIÓN DEL RADIOMANDO MEMORIZAÇÃO DO RADIOCOMANDO LEGENDA KEY LÉGENDE LEGENDE LEYENDA LEGENDA ALCOR AC A 3 D814011 00100_02 ...

Page 4: ...OT 2 PHOT CL BAR 8K2 50 52 50 52 50 51 50 51 50 51 50 51 50 70 72 70 72 73 70 70 72 73 BAR Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 1 BAR 1BAR CL 51 51 50 51 50 51 50 52 52 52 74 70 74 70 75 74 70 51 50 70 75 70 74 8 2Kohm 5 SAFETY EDGE SAFETY EDGE DIP2 OFF DIP4 OFF DIP4 ON DIP2 ON DIP3 OFF DIP3 ...

Page 5: ... For connection to the mains power supply use a multicore cable with a cross sectional area of at least 3x1 5mm2 of the kind provided for by the regulations in force To connect the motors use a cable with a cross sectional area of at least 1 5mm2 of the kind provided for by the regulations in force The cable must be type H05RN F at least 5 SAFETY DEVICES Note only use receiving safety devices with...

Page 6: ...C If not used leave jumper inserted BAR 8K2 dip Safety edge check dip Safety edge operation dip OFF OFF OFF NC input no verification reversal while opening and closing BAR OFF OFF ON NC input no verification reversal only when closing stop when opening BAR CL OFF ON OFF NC input with verification reversal while opening and closing BAR TEST OFF ON ON NC input with verification reversal only when cl...

Page 7: ... photocell is cleared 6 Safety edge input operation OFF ON Safety edge with active reversal only when closing when opening the movement stops OFF Safety edge with active reversal in both directions 7 Fast closing OFF ON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse OFF Logic not enabled 8 Residential apartment building operation OFF ON Sets the automati...