INSTALLATION MANUAL

ENGLISH

Terminal

De

fi

nition

Description

Po

w

er 

supply

L

LINE

Single-phase power supply 

N

NEUTRAL

M

ot

or

10

  START + CONDENSER

Motor and condenser connection

11

COM

12

START + CONDENSER

14

  START + CONDENSER

Connection between motor and capacitor 2. 

 Note: if T3=0 do not connect any cable to clamps 14-15-16

15

COM

16

START + CONDENSER

A

ux

20

AUX 0 – POWERED CONTACT 

230V (N.O.) (40W MAX)

Exit due to FLASHING LIGHT

Contact stays closed while leaves are operating.

21

A

cc

essories

po

w

er supply

50

0V-

Accessories power supply output.

51

24V+

52

24 Vsafe+

Tested safety device power supply output (photocell transmitter and safety edge transmitter). 

Output act ive only during operating cycle.

Commands

60

Common

START  and OPEN inputs common

61

START

START command button (N.O.).

Operation according to “Residential / apartment building operation” logic

62

OPEN

OPEN command button (N.O.).

Gate opened with this command. If the input stays closed, the leaves stay open until the 

contact is opened. 

When the contact is open, the automated device closes following the TCA time, where 

activated.

Saf

et

y de

vic

es

70

Common

STOP, PHOT and BAR inputs common

71

STOP 

The command stops movement. (N.C.) 

If not used, leave jumper inserted.

72

PHOT (*)

PHOTOCELL input (N.C.).

Operation according to “PHOTOCELL/PHOTOCELL DURING CLOSING” logic. If not used, leave 

jumper inserted.

73

FAULT 1 

Test input for safety devices connected to PHOT.

74

BAR / 

BAR CL / 

BAR TEST / 

BAR CL TEST /

BAR 8K2 / 

BAR CL 8K2 

 (*)

Safety edge input (N.C.).

If not used, leave jumper inserted

BAR/8K2 

dip

Safety edge 

check 

dip

Safety edge 

operation 

dip

OFF

OFF

OFF

NC input, no veri

fi

cation, reversal while 

opening and closing 

(BAR)

OFF

OFF

ON

NC input, no veri

fi

cation, reversal only 

when closing, stop when opening 

(BAR 

CL)

OFF

ON

OFF

NC input, with veri

fi

cation, reversal 

while opening and closing 

(BAR TEST)

OFF

ON

ON

NC input, with veri

fi

cation, reversal only 

when closing, stop when opening 

(BAR 

CL TEST)

ON

OFF

OFF

8K2 input, reversal when opening and 

closing 

(BAR 8K2)

ON

OFF

ON

8K2 input, reversal only when closing, 

stop when opening 

(BAR CL 8K2)

75

FAULT 2 

Test input for safety devices connected to BAR / BAR CL

A

nt

enna

Y

ANTENNA

Antenna input. 

Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. 

Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s 

range is limited, move the antenna to a more suitable position.

#

SHIELD

(*) If “D” type devices are installed (as de

fi

ned by EN12453), connect in unveri

fi

ed mode, foresee mandatory maintenance at least every six months.

(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.

TABLE “A” 

-

 PARAMETERS 

Any modi

fi

cation of parameters/logics must be con

fi

rmed by pressing S2 > 5s

       

TRIMMER

Parameter

+

min.

+

max.

+

default

Description

T1

Automatic 

closing time [s]

0

120

0

Waiting time before automatic closing.

NOTE: Set to 0 if not used.

T2

Work time [s]

5

90

50%

Adjusts the motors’ work time, lapsing which they will stop.

T3

Motor 1 closing 

delay time [s]

0

25

25%

Motor 1 closing delay time with respect to motor 2.

NOTE: set 0 for single motor operations (leaf 1).

ALCOR AC A

 

 -  

9

D814011 00100_02

Summary of Contents for ALCOR AC A

Page 1: ...UADRO DE MANDOS BEDIENINGSPANEEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen aan de binnenkant zorgvuldig D814011...

Page 2: ...xion d une paire de photocellules non vérifiées pour les photocellules vérifiées consultez les pages suivantes Anschluss von einem Paar nicht überprüfter Fotozellen für überprüfte Fotozelle siehe die folgenden Seiten Conexión de 1 par de fotocélulas no comprobadas para fotocélulas comproabdas véanse las siguientes páginas Aansluiting van 1 paar niet geverifieerde fotocellen Raadpleeg de volgende p...

Page 3: ...hen an Fijo Continu Lampeggio continuo Continuous flashing Clignotement continu Kontinuierliches Blinken Parpadeo continuo Continu knipperen MEMORIZZAZIONE RADIOCOMANDO MEMORIZING REMOTE CONTROLS MÉMORISATION RADIOCOMMANDE ABSPEICHERUNG DER FERNBEDIENUNG MEMORIZACIÓN DEL RADIOMANDO MEMORIZAÇÃO DO RADIOCOMANDO LEGENDA KEY LÉGENDE LEGENDE LEYENDA LEGENDA ALCOR AC A 3 D814011 00100_02 ...

Page 4: ...OT 2 PHOT CL BAR 8K2 50 52 50 52 50 51 50 51 50 51 50 51 50 70 72 70 72 73 70 70 72 73 BAR Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 1 BAR 1BAR CL 51 51 50 51 50 51 50 52 52 52 74 70 74 70 75 74 70 51 50 70 75 70 74 8 2Kohm 5 SAFETY EDGE SAFETY EDGE DIP2 OFF DIP4 OFF DIP4 ON DIP2 ON DIP3 OFF DIP3 ...

Page 5: ... For connection to the mains power supply use a multicore cable with a cross sectional area of at least 3x1 5mm2 of the kind provided for by the regulations in force To connect the motors use a cable with a cross sectional area of at least 1 5mm2 of the kind provided for by the regulations in force The cable must be type H05RN F at least 5 SAFETY DEVICES Note only use receiving safety devices with...

Page 6: ...C If not used leave jumper inserted BAR 8K2 dip Safety edge check dip Safety edge operation dip OFF OFF OFF NC input no verification reversal while opening and closing BAR OFF OFF ON NC input no verification reversal only when closing stop when opening BAR CL OFF ON OFF NC input with verification reversal while opening and closing BAR TEST OFF ON ON NC input with verification reversal only when cl...

Page 7: ... photocell is cleared 6 Safety edge input operation OFF ON Safety edge with active reversal only when closing when opening the movement stops OFF Safety edge with active reversal in both directions 7 Fast closing OFF ON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse OFF Logic not enabled 8 Residential apartment building operation OFF ON Sets the automati...