background image

50 51 52

70 71 72 73 74 75

24V 
~

24V 
~

24 VSafe

COM

PHOT

BAR

STOP

FAULT 1

FAULT 2

NC

NC

NC

PHOT

1

2

1

2
3

4

5

51

TX1

RX1

1

2

1

2
3

4

5

52

50

TX1

RX1

1

2

1

2
3

4
5

TX1

RX1

1

2

1

2
3

4
5

TX2

RX2

1

2

1

2
3

4

5

TX1

RX1

1

2

1

2
3

4

5

TX1

RX1

1

2

1

2
3

4
5

TX1

RX1

1

2

1

2
3

4
5

TX2

RX2

1 PHOT / 1 PHOT CL

1 PHOT / 1 PHOT CL

2 PHOT / 2 PHOT CL

BAR 8K2

50

52

50

52

50

51

50

51

50

51

50

51

50

70

72

70

72

73

70

70

72

73

BAR

Bar 1

1

2

3

4

5

6

Bar 1

1

2

3

4

5

Bar 2

1

2

3

4

5

Bar 1

1

2

3

4

5

6

6

6

Bar 1

1

2

3

4

5

6

Bar 1

1

2

3

4

5

Bar 2

1

2

3

4

5

Bar 1

1

2

3

4

5

6

6

6

1 BAR/ 1BAR CL

51

51

50

51

50

51

50

52

52

52

74

70

74

70

75

74

70

51

50

70

75

70

74

8,2Kohm 5%

SAFETY EDGE

SAFETY EDGE

DIP2 OFF

DIP4 OFF

DIP4 ON

DIP2 ON

DIP3 OFF

DIP3 ON

100

195

237

1 BAR TEST/ 1 BAR CL TEST

2 BAR TEST/ 2 BAR CL TEST

BAR 8K2/ BAR CL 8K2

F

G

4  -

  ALCOR AC A

D814011 00100_02

Summary of Contents for ALCOR AC A

Page 1: ...UADRO DE MANDOS BEDIENINGSPANEEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen aan de binnenkant zorgvuldig D814011...

Page 2: ...xion d une paire de photocellules non vérifiées pour les photocellules vérifiées consultez les pages suivantes Anschluss von einem Paar nicht überprüfter Fotozellen für überprüfte Fotozelle siehe die folgenden Seiten Conexión de 1 par de fotocélulas no comprobadas para fotocélulas comproabdas véanse las siguientes páginas Aansluiting van 1 paar niet geverifieerde fotocellen Raadpleeg de volgende p...

Page 3: ...hen an Fijo Continu Lampeggio continuo Continuous flashing Clignotement continu Kontinuierliches Blinken Parpadeo continuo Continu knipperen MEMORIZZAZIONE RADIOCOMANDO MEMORIZING REMOTE CONTROLS MÉMORISATION RADIOCOMMANDE ABSPEICHERUNG DER FERNBEDIENUNG MEMORIZACIÓN DEL RADIOMANDO MEMORIZAÇÃO DO RADIOCOMANDO LEGENDA KEY LÉGENDE LEGENDE LEYENDA LEGENDA ALCOR AC A 3 D814011 00100_02 ...

Page 4: ...OT 2 PHOT CL BAR 8K2 50 52 50 52 50 51 50 51 50 51 50 51 50 70 72 70 72 73 70 70 72 73 BAR Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 1 BAR 1BAR CL 51 51 50 51 50 51 50 52 52 52 74 70 74 70 75 74 70 51 50 70 75 70 74 8 2Kohm 5 SAFETY EDGE SAFETY EDGE DIP2 OFF DIP4 OFF DIP4 ON DIP2 ON DIP3 OFF DIP3 ...

Page 5: ... For connection to the mains power supply use a multicore cable with a cross sectional area of at least 3x1 5mm2 of the kind provided for by the regulations in force To connect the motors use a cable with a cross sectional area of at least 1 5mm2 of the kind provided for by the regulations in force The cable must be type H05RN F at least 5 SAFETY DEVICES Note only use receiving safety devices with...

Page 6: ...C If not used leave jumper inserted BAR 8K2 dip Safety edge check dip Safety edge operation dip OFF OFF OFF NC input no verification reversal while opening and closing BAR OFF OFF ON NC input no verification reversal only when closing stop when opening BAR CL OFF ON OFF NC input with verification reversal while opening and closing BAR TEST OFF ON ON NC input with verification reversal only when cl...

Page 7: ... photocell is cleared 6 Safety edge input operation OFF ON Safety edge with active reversal only when closing when opening the movement stops OFF Safety edge with active reversal in both directions 7 Fast closing OFF ON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse OFF Logic not enabled 8 Residential apartment building operation OFF ON Sets the automati...

Page 8: ...www bftme ae ...

Reviews: