TABLE “B” 

-

 LOGICS

Any modi

fi

cation of parameters/logics must be con

fi

rmed by pressing S2 > 5s

DIP

Logic

Default

Cross out  

setting used

Description

1

Transmitter  

programming

ON

ON

Enables wireless memorizing of transmitters:

1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been 

memorized in standard mode via the radio menu.

2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.

The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.

This mode does not require access to the control panel.

IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.

OFF

Disables wireless memorizing of transmitters and automatic addition of clones.

Transmitters are memorized only using the relevant Radio menu or automatically with replays.

IMPORTANT: Disables the automatic addition of new transmitters and clones

2

BAR / 8K2

OFF

ON 

Input con

fi

gured as Bar 8k2 (Fig.G). Input for resistive edge 8K2.

The command reverses movement for 1 sec.

OFF

Input con

fi

gured as Bar, safety edge (Fig.G).

The command reverses movement for 1 sec..

3

Photocell input 

check

OFF

ON

Enable safety check on the PHOT input. (Fig.G)

OFF

Safety check on PHOT input not enabled. (Fig.G)

4

Edge input check

OFF

ON

Enable safety check on the BAR input. (Fig.G)

OFF

Safety check on BAR input not enabled. (Fig.G)

5

Photocells 

during closing

OFF

ON

In the event beam is broken, photocell operation is disabled during opening. During closing, move-

ment is reversed immediately. 

OFF

When  beam  is  broken,  photocells  are  active  during  both  opening  and  clo-

sing.  When  beam  is  broken  during  closing,  movement  is  reversed  only  once  the  

photocell is cleared. 

6

Safety edge 

input operation

OFF

ON

Safety edge with active reversal only when closing, when opening the movement stops

OFF

Safety edge with active reversal in both directions

7

Fast closing

OFF

ON 

Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.

OFF

Logic not enabled

8

Residential / 

apartment 

building 

operation

OFF

ON

Sets the 

automation type 

of operation:

ON = Apartment building

Reaction to the 

START

 input (wired or radio):

Residential

Apartment building

CLOSED

Opens

Opens

WHILE CLOSING

Stops

Opens

OPEN

Closes

Closes

WHILE OPENING

STOPS + TCA

No e

ff

ect

AFTER STOP

Opens

Opens

Reaction to the 

OPEN

 input (wired):

Residential

Apartment building

CLOSED

Opens

Opens

WHILE CLOSING

Opens

Opens

OPEN

Keep open + TCA

Keep open + TCA

WHILE OPENING

No e

ff

ect

No e

ff

ect

AFTER STOP

Opens

Opens

Reaction to the 

PEDESTRIAN

 input (radio):

Residential

Apartment building

CLOSED

Opens partially

Opens partially

WHILE CLOSING

Stops

Opens partially

OPEN

Closes

Closes

WHILE OPENING

STOPS + TCA

No e

ff

ect

AFTER STOP

Opens partially

Opens partially

OFF

OFF = Residential

9

Hammer during 

opening

OFF

ON

Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the sole-

noid lock to be released more easily. 

IMPORTANT - Do not use this function if suitable mechanical stops are not in place.

OFF

Logic not enabled

10

Stop 

maintenance

OFF

ON

If motors stay idle in fully open or fully closed position for more than one hour, they are switched on 

in the direction of the stop for approx. 3 seconds. This operation is performed every hour.  

NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil 

due to a drop in temperature during extended pauses, such as during the night, or due to internal 

leakage. 

IMPORTANT - Do not use this function if suitable mechanical stops are not in place.

OFF

Logic not enabled

10  -

  ALCOR AC A

D814011 00100_02

Summary of Contents for ALCOR AC A

Page 1: ...UADRO DE MANDOS BEDIENINGSPANEEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen aan de binnenkant zorgvuldig D814011...

Page 2: ...xion d une paire de photocellules non vérifiées pour les photocellules vérifiées consultez les pages suivantes Anschluss von einem Paar nicht überprüfter Fotozellen für überprüfte Fotozelle siehe die folgenden Seiten Conexión de 1 par de fotocélulas no comprobadas para fotocélulas comproabdas véanse las siguientes páginas Aansluiting van 1 paar niet geverifieerde fotocellen Raadpleeg de volgende p...

Page 3: ...hen an Fijo Continu Lampeggio continuo Continuous flashing Clignotement continu Kontinuierliches Blinken Parpadeo continuo Continu knipperen MEMORIZZAZIONE RADIOCOMANDO MEMORIZING REMOTE CONTROLS MÉMORISATION RADIOCOMMANDE ABSPEICHERUNG DER FERNBEDIENUNG MEMORIZACIÓN DEL RADIOMANDO MEMORIZAÇÃO DO RADIOCOMANDO LEGENDA KEY LÉGENDE LEGENDE LEYENDA LEGENDA ALCOR AC A 3 D814011 00100_02 ...

Page 4: ...OT 2 PHOT CL BAR 8K2 50 52 50 52 50 51 50 51 50 51 50 51 50 70 72 70 72 73 70 70 72 73 BAR Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 1 BAR 1BAR CL 51 51 50 51 50 51 50 52 52 52 74 70 74 70 75 74 70 51 50 70 75 70 74 8 2Kohm 5 SAFETY EDGE SAFETY EDGE DIP2 OFF DIP4 OFF DIP4 ON DIP2 ON DIP3 OFF DIP3 ...

Page 5: ... For connection to the mains power supply use a multicore cable with a cross sectional area of at least 3x1 5mm2 of the kind provided for by the regulations in force To connect the motors use a cable with a cross sectional area of at least 1 5mm2 of the kind provided for by the regulations in force The cable must be type H05RN F at least 5 SAFETY DEVICES Note only use receiving safety devices with...

Page 6: ...C If not used leave jumper inserted BAR 8K2 dip Safety edge check dip Safety edge operation dip OFF OFF OFF NC input no verification reversal while opening and closing BAR OFF OFF ON NC input no verification reversal only when closing stop when opening BAR CL OFF ON OFF NC input with verification reversal while opening and closing BAR TEST OFF ON ON NC input with verification reversal only when cl...

Page 7: ... photocell is cleared 6 Safety edge input operation OFF ON Safety edge with active reversal only when closing when opening the movement stops OFF Safety edge with active reversal in both directions 7 Fast closing OFF ON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse OFF Logic not enabled 8 Residential apartment building operation OFF ON Sets the automati...

Page 8: ...www bftme ae ...

Reviews: