INSTALLATION MANUAL
TABLE “B”
-
LOGICS
Any modi
fi
cation of parameters/logics must be con
fi
rmed by pressing S2 > 5s
DIP
Logic
Default
Cross out
setting used
Description
1
Transmitter
programming
ON
ON
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
OFF
Disables wireless memorizing of transmitters and automatic addition of clones.
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
2
BAR / 8K2
OFF
ON
Input con
fi
gured as Bar 8k2 (Fig.G). Input for resistive edge 8K2.
The command reverses movement for 1 sec.
OFF
Input con
fi
gured as Bar, safety edge (Fig.G).
The command reverses movement for 1 sec..
3
Photocell input
check
OFF
ON
Enable safety check on the PHOT input. (Fig.G)
OFF
Safety check on PHOT input not enabled. (Fig.G)
4
Edge input check
OFF
ON
Enable safety check on the BAR input. (Fig.G)
OFF
Safety check on BAR input not enabled. (Fig.G)
5
Photocells
during closing
OFF
ON
In the event beam is broken, photocell operation is disabled during opening. During closing, move-
ment is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
6
Safety edge
input operation
OFF
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
Safety edge with active reversal in both directions
7
Fast closing
OFF
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Logic not enabled
8
Residential /
apartment
building
operation
OFF
ON
Sets the
automation type
of operation:
ON = Apartment building
Reaction to the
START
input (wired or radio):
Residential
Apartment building
CLOSED
Opens
Opens
WHILE CLOSING
Stops
Opens
OPEN
Closes
Closes
WHILE OPENING
STOPS + TCA
No e
ff
ect
AFTER STOP
Opens
Opens
Reaction to the
OPEN
input (wired):
Residential
Apartment building
CLOSED
Opens
Opens
WHILE CLOSING
Opens
Opens
OPEN
Keep open + TCA
Keep open + TCA
WHILE OPENING
No e
ff
ect
No e
ff
ect
AFTER STOP
Opens
Opens
Reaction to the
PEDESTRIAN
input (radio):
Residential
Apartment building
CLOSED
Opens partially
Opens partially
WHILE CLOSING
Stops
Opens partially
OPEN
Closes
Closes
WHILE OPENING
STOPS + TCA
No e
ff
ect
AFTER STOP
Opens partially
Opens partially
OFF
OFF = Residential
9
Hammer during
opening
OFF
ON
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the sole-
noid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
OFF
Logic not enabled
10
Stop
maintenance
OFF
ON
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on
in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil
due to a drop in temperature during extended pauses, such as during the night, or due to internal
leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
OFF
Logic not enabled
10 -
ALCOR AC A
D814011 00100_02
Summary of Contents for ALCOR AC A
Page 8: ...www bftme ae ...