position to fully warm up. During this time a slight odour may be
noticed, this is due to the “newness” of the fire and will soon disappear.
f)
Finally, hand the Installation and Maintenance Instructions / Users
Instructions over to the customer and explain the operation of the fire.
3.4
REMOVAL / RE-FITTING OF THE EFFICIENCY BAFFLE
a)
Remove the glass panel as shown in section 2.6
b)
The efficiency baffle if fitted to the inner roof of the combustion chamber
and is secured by 2 off screws.
c)
Remove the screws and pull the efficiency baffle downwards to remove
from the appliance.
d)
Replace in reverse order.