SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a
GAS SAFE registered engineer. It is a condition of BFM Fires lifetime
guarantee scheme that this is carried out by a competent person in
accordance with these servicing notes, and must include an oxy-pilot
change. The condition of the logs should be checked and if necessary the
whole set should be replaced with a genuine replacement set. After any
servicing work a gas tightness check must always be carried out. BEFORE
ANY SERVICING WORK IS CARRIED OUT ENSURE THE PRODUCT HAS
BEEN DISCONNECTED FROM THE ELECTRICITY SUPPLY.
4.1
Removing the burner assembly from the fire.
4.1.1
Attach the glass panel clamp as shown in section 2.7
4.1.2
Remove the side trims and base trim as shown in section 2.7
4.1.3
Remove the glass panel retaining bracket by removing the 5 off
retaining screws as shown in section 2.7
4.1.4
Remove the glass panel as shown in section 2.7
4.1.5
Remove the logs and vermiculite from the burner tray.
4.1.6
Remove the burner tray cover by lifting clear.
4.1.7
Remove the burner retaining screws as shown in section 2.8
4.1.8
Remove the on/off switch from it’s retaining bracket on the right hand
side as shown in section 2.8
4.1.9
Isolate the gas supply at the inlet elbow then disconnect the burner inlet
pipe as shown in section 2.8
4.1.10
Lift the burner and tilt forwards from the combustion chamber to
remove, as shown in section 2.8
4.2
Removing the gas control valve from the fire.
4.2.1
Remove the burner from the combustion chamber as described in
section 4.1 above.
4.2.2
Disconnect the inlet, outlet, pilot pipes and thermocouple connection
from the control valve.
31