Maintenance
5-24
Maintenance
Manual No. 101300
Operating Instructions and Parts List for the Whizard
Quantum
®
Trimmer
March 16, 2015
OPTIONAL DISC GAUGE OR DEPTH GAUGE INSTALLATION AND
ADJUSTMENT
Optional Disc Gauges for
Models Q850, Q1850, Q1000
and Q1300
Optional adjustable disc gauges are available
for the Q850, Q1850, Q1000 and Q1300
trimmers.
Refer to Section 7, Service Parts to
order.
•
Slide the disc gauge downward along the
cover plate grooves until the disc gauge
clamps catch in position.
•
The final height adjustment can be made
after the blade is installed.
•
Tighten the two attachment screws.
Adjustment
•
Hold the handpiece with the blade facing
downward.
•
Turn the adjustment knob clockwise for a thicker cut, or counterclockwise for a thinner cut.
NOTE:
Take care not to turn too far as the depth control hub may disengage from the shaft.
ATTACHMENT
SCREWS (2)
ADJUSTMENT KNOB
DEPTH / DISC GAUGE