OPERATING ANTI-WIND UP SYSTEM
1. Set the ‘direction selector of the anti-wind up system’ to the proper operating direction:
- clockwise operation / bolt tightening
- neutral position - centre the ‘direction selector of the anti-wind up system’ and fix it by
means of a hexagon driver. Before operating the anti-wind up system, check that the
input square can rotate freely in both directions.
- counterclockwise operation / bolt release.
Test the direction of rotation and make sure that the system operates freely.
o CW = clockwise
o CCW = counterclockwise
o N = normal
DO NOT USE THE TOOL IF THE DEVICE DOES NOT OPERATE FREELY.
2. To apply the torque, follow the instructions for setting and using the torque multiplier
above. Set the direction of operation for the anti-wind up system as shown in Figure 4.
3. To remove the torque multiplier, accurately load the gear cover until the ‘direction selector
of the anti-wind up system’ can be moved into the neutral position. Allow the torque
wrench to rotate slowly, until the torque multiplier can run freely.
a.
Load the torque wrench.
FIGURE
4
TORQUE MULTIPLIERS with anti-wind up system