BestCode Next Series 8 Technical Manual
October 2022
Page 172 of 290
Prompt Code
Prompt Name
Prompt Description
0B-0003
Override Warn
300 Volt supply not detected.
Occurs when enabling Errors from the Service Screen.
Solution 1:
Perform modulation calibration (including setting the Charge% to normal range.)
Solution 2:
Check for Disconnected Blue or Yellow Coax cables.
Solution 3:
Replace the Main Circuit Board
Solution 4:
Replace the Power Supply
Solution 5:
Replace the Printhead Umbilical
Prompt Code
Prompt Name
Prompt Description
0B-0004
Override Warn
Modulation voltage not detected.
Occurs when enabling Phase from the Service Screen.
Solution 1:
Check for Disconnected Blue Coax cable and Printhead Ground wire.
Solution 2:
If no Droplets visible, replace Drop Generator.
Solution 3:
Replace the Printhead Umbilical
Solution 4:
Replace the Main Circuit Board
Solution 5:
Replace the Power Supply
Prompt Code
Prompt Name
Prompt Description
0C-8001
Fan Cooling
Fan rotation not detected.
Solution 1:
Plug in the fan
Solution 2:
Replace the Fan
Prompt Code
Prompt Name
Prompt Description
0C-8002
Air Cooling
Air cooling pressure not detected.
Solution 1:
Plug in the -DRY pressure transducer cable to J26 Air Cooler on the Main Circuit Board
Solution 2:
Increase air pressure or tighten air regular on the -DRY air separator until at least 40 PSI is read on the
pressure gauge.
Solution 3:
Tighten the printhead air flow valve in the electronic compartment to reduce air flow to the printhead.
This will increase air pressure at the -DRY pressure transducer.
Prompt Code
Prompt Name
Prompt Description
0C-8003
Temperature
System temperature too high to operate.
Solution 1:
Ambient Temperature in the Controller is too high.
Solution 2:
If on screen temperature reading is not accurate, replace the Main Circuit Board
Prompt Code
Prompt Name
Prompt Description
OD-0001
Success
-
Indicates that a Pump SmartLabel was successfully scanned.
Prompt Code
Prompt Name
Prompt Description
0D-8001
Not Used
-
Solution 1:
Load new Firmware.
Summary of Contents for Next 8 Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 143: ...BestCode Next Series 8 Technical Manual October 2022 Page 129 of 290 USB ...
Page 144: ...BestCode Next Series 8 Technical Manual October 2022 Page 130 of 290 Collector Information ...
Page 259: ...BestCode Next Series 8 Technical Manual October 2022 Page 245 of 290 ...
Page 264: ...BestCode Next Series 8 Technical Manual October 2022 Page 250 of 290 ...
Page 268: ...BestCode Next Series 8 Technical Manual October 2022 Page 254 of 290 ...
Page 276: ...BestCode Next Series 8 Technical Manual October 2022 Page 262 of 290 Using the Molex Crimper ...
Page 277: ...BestCode Next Series 8 Technical Manual October 2022 Page 263 of 290 ...