background image

6

ENGLISH

Parts of the Body to Work Out Using Gymform® DUO IMPULSE:

Each Gymform® DUO IMPULSE device allows you to work out 2 adjacent 

muscles at the same time:

1. Pectorals

2. Upper abs

3. Lower abs

4. Obliques

5. Glutes

6. Trapezius muscles

7. Calves

8. Inner thighs 

9. Outer thighs

You can work out many different combinations of adjacent muscles. You choose 

the muscles you want to work out. Here are some suggestions:

10. Lower front thigh + upper front thigh

11. Upper outer front thigh + upper outer rear thigh

12. Arms:  triceps

13. Arms:  forearms

INSTRUCTIONS

After placing the self-adhesive electrodes (3) on the parts of the body 

to be treated, turn on the receivers (2) by pressing the button (5) with the           or 

ON/OFF symbol. Next, use the remote control (1) to choose from among 6 different 

programmes and 10 intensity levels.

• ON/+ button to turn on and increase intensity (6): Press this button to turn on the 

receivers and increase the stimulation intensity. Each time you press the button, 

the intensity level will be increased by one level (1-10). There are 10 levels in 

total.

• OFF/- button to turn off and reduce intensity (8): Press this button to turn off the 

receivers and reduce the stimulation intensity. Each time you press the button, 

the intensity level will be reduced by one level (1-10). There are 10 levels in total. 

The receivers can be turned off by pressing the button to the lowest intensity 

level. 

• There are 10 stimulation intensity levels. Level 10 is the one that provides the 

most stimulation.

• You can change programmes at any time by pressing the Mode button (7).  Each 

time you press it, a different programme will start at the minimum intensity level. 

You can change this to your desired intensity level using the + button. 

• There are 6 Gymform® DUO IMPULSE programmes. Choose the one you like 

best.

• The maximum recommended time for use on each part of the body is 10 minu-

tes.

• After using the product, switch off the receivers by pressing the ON/OFF button 

with the   symbol.  

GYMFORM® DUO IMPULSE PROGRAMMES

Programme Function  

LED 1 

LED 2   LED 3  

LED 4 

   

 

Red 1  

Yellow 1  Red 2  

Yellow 2

1  

Massage 

On 

Off 

Off 

Off

2  

Muscle Building  Off 

On 

Off 

Off

3

  

Anti-Cellulite

   

Slimming I  

On 

On Off  Off

4  

Slimming II 

Off 

Off 

On 

Off

5  

Anti-Cellulite  Off 

Off 

Off 

On

6  

Fitness 

Off 

Off 

On 

On

TECHNICAL SPECIFICATIONS

Batteries: the unit runs on 5x3V CR-2032

Maximum power consumption: 15 mA (RMS) (Load: 500Ω)

Impulse frequency: 0.2Hz ~ 250Hz

Automatic shutoff time: 15 ± 3 minutes

Modes: 6 programmes to choose from 

Impulse intensity control: 10 intensity levels to choose from

Impulse intensity upon choosing a programme: the intensity level starts at one 

each time you select a different programme.

Dimensions: 24cm x  6cm x 2cm // 7cm x 3,5cm x 1,3cm

Weight: 140gr

 

This symbol indicates that the device is protected against electrosta-

tic discharge by BF-type double insulation. 

Fig. 1

                ISO 7000-1641 User Guide

CLEANING AND MAINTENANCE

DO NOT WASH Gymform® DUO IMPULSE. WIPE WITH A DRY OR DAMP CLOTH. 

Remove the batteries from your Gymform® DUO IMPULSE if you do not plan to use 

it for an extended period of time.

MAINENANCE AND STERILIZATION OF ADHESIVE ELECTRODES

-  Do not immerse in water.

-  Keep in a cool, dry place at room temperature.

-  Do not remove the insulating label.

- After using the device, always replace the protective plastic backings on the 

adhesive electrodes.

-  Store in the bag supplied.

-  Sterilize by wiping with wet fingers.

PRECAUTIONS WITH BATTERIES

Ensure the batteries are properly installed before turning the unit on.

Turn off the unit to change the batteries.

Remove the batteries if you are not going to use the device for an extended period 

of time.

Take the necessary precautions when disposing of the batteries. Do not expose 

them to fire.

DISPOSAL OF MATERIALS

A symbol of a crossed-out wheeled bin  means you should find out 

about and follow local regulations about disposing of this kind of 

product.

Do not dispose of this product as you would other household waste. 

Dispose of this device in accordance with the corresponding local 

regulations.

Electrical and electronic devices contain hazardous substances that can have 

harmful effects on the environment and/or human health and should be recycled 

properly.

The battery should be disposed of separately. To protect the environment, all bat-

teries, including rechargeable ones, should not be disposed of as you would other 

household waste. Take them to a disposal centre and ensure it complies with appli-

cable legislation on battery disposal.

Quality Warranty:

This product is covered by a warranty against manufacturing defects subject to the 

time periods stipulated by the legislation in force in each country.

This warranty does not cover damages resulting from inadequate use, negligent 

commercial use, abnormal wear and tear, accidents or improper handling.

Australia & New Zealand only

This product has the benefit of certain Consumer Guarantees. These are prescri-

bed by the Australian Consumer Law & the New Zealand Consumer Guarantees 

Act 1993 both of which provide protection for consumers.  There is no express 

warranty for this product in Australia or New Zealand.  The above paragraph refers 

to other countries.

Made in China.

Summary of Contents for GYM form Duo IMPULSE

Page 1: ...International patents pending All imitations will be prosecuted GYMFORM DUO IMPULSE is a registered EU CTM trade mark ...

Page 2: ...2 3 5 4 7 6 8 1 ...

Page 3: ......

Page 4: ......

Page 5: ...our menstrual period Before using Gymform DUO IMPULSE you should obtain permission from your doctor or physiotherapist If you suffer from back problems In this case the device should only be used at low intensity levels If you suffer from a serious disease or injury not mentioned in this section If you were operated on recently If you are diabetic and take insulin Do not place one receiver on your...

Page 6: ...Impulse intensity control 10 intensity levels to choose from Impulse intensity upon choosing a programme the intensity level starts at one each time you select a different programme Dimensions 24cm x 6cm x 2cm 7cm x 3 5cm x 1 3cm Weight 140gr This symbol indicates that the device is protected against electrosta tic discharge by BF type double insulation Fig 1 ISO 7000 1641 User Guide CLEANING AND ...

Page 7: ...cha fiebre Señoras para usar Gymform DUO IMPULSE deben esperar hasta que pasen Al menos seis meses tras el nacimiento de su hijo previa consulta con su mé dico Un mes después de la colocación de un anticonceptivo intrauterino Al menos tres meses después de una cesárea previa consulta con su médico Los primeros días del período Para usar Gymform DUO IMPULSE debe obtener el permiso de su médico o fi...

Page 8: ... 1 LED 2 LED 3 LED 4 rojo 1 amarillo 1 rojo 2 amarillo 2 1 Masaje Enc Apag Apag Apag 2 Musculación Apag Enc Apag Apag 3 Anticelulítico Adelgazamiento I Enc Enc Apag Apag 4 Adelgazamiento II Apag Apag Enc Apag 5 Anticelulítico Apag Apag Apag Enc 6 Fitness Apag Apag Enc Enc ESPECIFICACIONES TÉCNICAS Alimentación 5 pilas CR 2032 de 3 V Consumo máximo de corriente 15 mA RMS Carga 500 Ohm Frecuencia de...

Page 9: ...frez d un problème cardiaque Si vous êtes enceinte ou si vous pensez que vous pouvez l être Si vous êtes atteint e d un cancer d épilepsie ou si vous êtes suivi e par un médecin suite à des troubles cognitifs Si vous allaitez Si vous avez de la fièvre Mesdames avant d utiliser Gymform DUO IMPULSE vous devez attendre Au moins six mois après la naissance de votre enfant et après en avoir parlé avec ...

Page 10: ...récepteurs en appuyant sur le bouton 5 orné du symbole PROGRAMMES GYMFORM DUO IMPULSE Programme Fonction LED 1 LED 2 LED 3 LED 4 rouge 1 jaune 1 rouge 2 jaune 2 1 Massage Allumé Éteint Éteint Éteint 2 Musculation Éteint Allumé Éteint Éteint 3 Anticellulite Amincissement I Allumé Allumé Éteint Éteint 4 Amincissement II Éteint Éteint Allumé Éteint 5 Anticellulite Éteint Éteint Éteint Allumé 6 Fitnes...

Page 11: ...it Wenn Sie hohes Fieber haben Hinweis für Frauen Um Gymform DUO IMPULSE gebrauchen zu können müs sen Sie folgende Zeitspannen abwarten Mindestens sechs Monate nach der Geburt Ihres Kindes bitte erst mit Ihrem Arzt Rücksprache nehmen Einen Monat nachdem ein Intrauterinpessar eingesetzt wurde MindestensdreiMonatenacheinemKaiserschnitt bitteerstmitIhremArztRückspra che nehmen Die erstenTage der Mens...

Page 12: ... der Ein Aus Taste 5 mit dem Zeichen aus PROGRAMME DES GYMFORM DUO IMPULSE Programm Funktion LED1 LED2 LED3 LED4 rot1 gelb1 rot2 gelb2 1 Massage Leuchtet Leuchtetnicht Leuchtetnicht Leuchtetnicht 2 Muskelbildung Leuchtetnicht Leuchtet Leuchtetnicht Leuchtetnicht 3 Anti Cellulite Wirkung AbnehmenI Leuchtet Leuchtet Leuchtetnicht Leuchtetnicht 4 AbnehmenII Leuchtetnicht Leuchtetnicht Leuchtet Leucht...

Page 13: ... nullaosta del proprio medico curante I primi giorni del ciclo mestruale Per utilizzare Gymform DUO IMPULSE si deve avere il nullaosta del proprio medico curante o di un fisioterapista nei seguenti casi Se si hanno problemi di schiena In questi casi ci si deve inoltre assicurare di mante nere l intensità su livelli bassi Se si ha qualche malattia o ferita grave non citata in questa sezione Se si è...

Page 14: ...ntazione 5 pile CR 2032 da 3V Consumo di corrente massimo 15 mA RMS Carica 500 Ohm Frequenza degli impulsi 0 2 Hz 250 Hz Tempo per lo spegnimento automatico 15 3 minuti Modi 6 programmi selezionabili Intensità degli impulsi 10 livelli d intensità selezionabili Intensità degli impulsi quando si seleziona un programma ogni volta che si seleziona un nuovo programma il livello degli impulsi inizia da ...

Page 15: ...u médico Um mês após a colocação de um contracetivo intrauterino No mínimo três meses após uma cesariana com consulta prévia ao seu médico Os primeiros dias do período Para utilizar o Gymform DUO IMPULSE deve contar com a autorização do seu médico ou fisioterapeuta Se tiver problemas nas costas Deve assegurar se ainda que a intensidade se man tém nos níveis baixos Se sofrer de uma doença ou ferida...

Page 16: ...sligado Desligado Ligado Desligado 5 Anticelulite Desligado Desligado Desligado Ligado 6 Fitness Desligado Desligado Ligado Ligado ESPECIFICAÇÕESTÉCNICAS Alimentação 5 pilhas CR 2032 de 3V Consumo máximo de corrente 15 mA RMS Carga 500 Ohm Frequência de impulsos 0 2 Hz 250 Hz Tempo de desligação automática 15 3 minutos Modos 6 programas selecionáveis Regulação da intensidade dos impulsos 10 níveis...

Page 17: ...n na de geboorte van uw baby in overleg met uw arts Eén maand na het inbrengen van een intra uterien anticonceptiemiddel Ten minste drie maanden na een keizersnede in overleg met uw arts De eerste dagen van de menstruatie VoorhetgebruikvanGYMFORM DUOIMPULSEheeftutoestemmingvanuwarts of fysiotherapeut nodig Indienurugklachtenheeft Udienterookvoortezorgendatudeintensiteitopdelage niveaus houdt Indie...

Page 18: ...ood 2 geel 2 1 Massage Aan Uit Uit Uit 2 Spiertraining Uit Aan Uit Uit 3 Anticellulitis Afslanken I Aan Aan Uit Uit 4 Afslanken II Uit Uit Aan Uit 5 Anticellulitis Uit Uit Uit Aan 6 Fitness Uit Uit Aan Aan TECHNISCHE GEGEVENS Voeding 5 CR 2032 batterijen van 3V Maximaal stroomverbruik 15 mA RMS Weerstand 500 Ohm Pulsfrequentie 0 2 Hz 250 Hz Automatische uitschakeltijd 15 3 minuten Modi 6 selecteer...

Page 19: ......

Page 20: ......

Reviews: