82527 Vantage
32
Phases
Rinsed
components Liquid used
Valve
position
(4)
Power take-
off
Position of the
control switch
Location
Comments
1
Rinsing the main tank, the hopper and mixing circuits with the rinsing tank
Main tank
Fresh water
300 rpm
maximum
1, 2
Work to be done
in the field
Hopper
Activate the accessories
2
Rinse the spray circuit with the rinsing tank
Boom
Fresh water
300 rpm
maximum
1, 2
Work to be done
in the field
Spray the residual liquid on
the crops
3
Rinse all the circuits with the main tank
Mixing
Fresh water
+ cleaning
product
300 rpm
maximum
1, 2
Recovery area on
the farm
Each phase must be done in
10 minutes for correct cleaning
Boom
1, 2
1 to 3
WARNING:
The valve for the return manifold (3) must remain closed during these operations.
4
Rinsing the return manifold and the boom
Boom
Fresh water
300 rpm
maximum
1, 2
Recovery area on
the farm
Valve (3)
Valve (3) position
WARNING:
Do not perform this action if any treatment product remains in the tank.
5
Final rinsing of the machine
Valve (3)
Fresh water
300 rpm
maximum
1, 2
Recovery area on
the farm
Valve (3) position
Main tank
1, 2
Hopper
Mixing
Boom
1, 2
4.7 RINSING THE MACHINE IN DUALELEC
The table above presents the sequence for opening
and closing the valves (or switches). The purpose of
this operation is to clean all of the circuits.
WARNING:
Restart the operation if any residue
remains after rinsing.
5780 L
25%
5780
0.0
Km/h
0
L/ha
3.00
bar
user
exemple_p_const
0.00 Ha
R
05 - PULVERISATION
1
2
51
11
11
11
2
5
3
4
7 8
9
1
2
3
4
6
6
4
5
5
10
3
2
2
1 4
9
8
8
9
3
1
10
7
7
10
6
1
1 EXTERIOR SUCTION
2 INCORPORATION WATER MAIN TANK
3 INCORPORATION WATER EXTERIOR SUCTION
4 INCORPORATION WATER RINSING TANK
5 SPRAYING
6 CLEANING TANK WITH RINSE TANK
7 RINSING BOOM WITH RINSE TANK
8 TRANSFER
9 CLEANING FILTER
10 AUXILIARY SUCTION OPTION
11 EXTERIOR WASHING OPTION
52
4
4
5
3
Summary of Contents for VANTAGE E.C.TRONIC 28-30