Control Unit Indicators
(Continued)
LED Error
This LED (Fig. 2, Pos. 1) lights up if an error has occurred. The
current measurement is retained. Check the device settings. All
possible error reports are described in chapt. 8 Troubleshooting
.
Warning LED
This LED (Fig. 2, Pos. 2) lights up if calibration is being carried
out or if the device is in test mode or if any other warning mes-
sage is present. The current measurement is retained. All possi-
ble error reports are described in chapt. 8 Troubleshooting .
Run LED
This LED (Fig. 2, Pos. 3) lights up if the device is in operation and
fault-free. The current measurement is carried out.
3.4.3
Back View
The following connections are located on the back of the EVU:
EVU power supply
Power supply of channels 1 to 4
Measurement inputs from the GAMMAcast detector for the channels 1 to
4
Ethernet port for the data transmission via the LAN connection
USB ports for the external USB devices
Summary of Contents for castxpert LB 452
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ...c 2 Safety 14 Rev 04 03 2015 b ...
Page 22: ......
Page 40: ......
Page 120: ......
Page 138: ......
Page 140: ...c 10 Decommissioning 140 Rev 04 03 2015 b ...
Page 146: ...c 11 Technical Information 146 Rev 04 03 2015 b 11 4 c LB 452 Connections Rear Overview ...
Page 151: ...c 12 Declaration of Conformity b Rev 04 03 2015 151 12Declaration of Conformity ...
Page 152: ...c 12 Declaration of Conformity 152 Rev 04 03 2015 b ...
Page 155: ...c 13 Index b Rev 04 03 2015 155 ...