29
Installation Instructions
The RolloTec
®
insert can only be set into operation in conjunction with one of the
following attachments:
RolloTec
®
pushbutton
RolloTec
®
radio control pushbutton
RolloTec
®
memory pushbutton
RolloTec
®
clock timer attachment module Easy
RolloTec
®
clock timer attachment module
Install the RolloTec
®
insert
in a connecting box according to DIN 49073
(recommendation: deep box).
The connection terminals of the insert must be in downward position.
Plug attachment
onto the insert, together with frame
.
Electrical contacting is established through plug
.
For the attachment with sensor evaluation, additional plug-in contacts
must be led
into the insert to connect a sensor line. The sensor must be connected by screw
terminals.
Installation Instructions
28
C
Sun
Glass
Earth
Surface installation (RolloTec
®
timer with sensor evaluation) (Illustration C):
The sensor or adapter must be connected to the attachment by a plug.
Connect to the terminal block in the insert:
Connect sensor lines as shown in the opposite diagram (illustration).
Markings of the line wires:
Sensors
: ‘Earth’ = marked.
Adapter, extension line
: ‘Sun’ = marked.
‘Earth’ = middle wire.
If a sun/twilight sensor and a glass breakage sensor are to be run at the same time,
use an adapter (not within the scope of supplies). Connect the adapter to the
attachment with sensor evaluation or to the insert via the three-pole terminal. The
adapter has two jacks for the connection of the sensor plugs.