![Berges ACP micro 3000 Operating Manual Download Page 71](http://html.mh-extra.com/html/berges/acp-micro-3000/acp-micro-3000_operating-manual_2736999071.webp)
21.12.98
Operating manual
04_GB
ACP 3000 — 0.37–15.0
67
Berges electronic
•
D–51709 Marienheide-Rodt
•
Tel. 02264/17-0
•
Fax 02264/17126
9.2
Parameters Added or Amended when PI Control is Utilized
The following table lists the parameters that become available when PI control is enabled
by setting parameter
81-PRGNO
to a value between 80 and 95 (see page 56). It also lists
those parameters where data codes change due to the enabling of P1 control. For further
information on PI control, see section 6 starting on page 51.
9.3
Options
A.
XRK01 – Remote Keypad Unit
The XRK01 – Remote Keypad Unit (RKU) is a portable, hand held accessory. When con-
nected to an ACP 3000-inverter, it will function in parallel with an existing keypad or allow
a chassis model to be controlled and programmed. The RKU is powered by a 9 V alkaline
battery (supplied) or an optional AC adapter (PA24DC). Auto Power Down and backlight
control features conserve battery life by automatically turning the RKU off after a specified
time period and allowing selected use of the display backlight.
PARAMETER
LEVEL
RANGE (DEFAULT)
USER SETTING
SEE
PAGE
Parameters That Are Added When PI Control Is Enabled:
1A-FSTAT
Stator Frequency
2
–
Read-only
A1-FCORR
Frequency Correction
2
0.00–400.0 Hz
A6-ERROR2 Final Error
2
–
Read-only
A7-ERROR1 Initial Error
2
–
Read-only
A8-SIPART
Integral Sum
2
–
Read-only
B3-KP
Proportional Gain
2
0–255
B4-KI
Integral Gain
2
0–255
B5-KIN
VIN1 Scaling
2
0–255
Parameters That Are Amended When PI Control Is Enabled:
21-MODE
Input Mode
1
If PS3 is used for on/off control, preset speed
switch and jog/run are not available.
24-FSEL
Speed Setpoint Selector
2
Four data codes area added; range is now 0–3
and 16–19.
41-RSEL
Ramp Selector
2
If PS3 is used for on/off control, Alternate Ramp
Time (ART) is not available. Range is now 0–2
and 4–6 (data codes 3 & 7 are disabled).
65-SLIP
Slip Compensation
1
This parameter is disabled.
71-METER
Analog Meter Output Selector
MET1
1
Data codes 5 is added; the range is now 0–5.
79-MET2
Analog Meter Output Selector
MET2
1
Two data codes are added; the range is now 0–5
and 11–15.
81-PRGNO
Special Program
2
Data codes 80–95 added to select type of PI con-
trol desired.
StockCheck.com