Operating manual
21.12.98
ACP 3000 — 0.37–15.0
04_GB
32
4.6
Status Indicator
The STATUS indicator consists of two LEDs, one green and one red located in the upper
right corner of the control board. They are visible through a lens in the upper right corner of
the keypad on IP 21 models. The following table defines the STATUS indicator state for the
various operating conditions of the inverter:
4.7
Description of Displays
The back-lit, LCD display provides information on drive operation and programming. The
four large 7-segment displays show drive output and programming data. The two smaller
digits are used to indicate parameter numbers in the Program mode. Special symbols and
displays provide further clarification of drive operation. Figure 4.2 shows all segments dis-
played. In normal operation only those segments that are active are displayed.
Table 4.4 lists the special annunciators and their meaning:
STATUS INDICATION
OPERATING CONDITION
COLOUR
DURATION
Green and Red Continuous Power on, restart (2 Seconds)
Red
Continuous Stop, running in torque limit
Green
Continuous Run
Green and Red Flashing
Running in and out of torque limit
Red
Flashing
Fault condition, Emergency Stop, line start lock-out, or low-
voltage
Green
Flashing
Running in and out of an overvoltage or undervoltage con-
dition
Table 4.3
Figure 4.2
SYMBOL
DESCRIPTION
FWD
Forward direction commanded
REV
Reverse direction commanded
PRG
Continuous: Program mode selected.
Flashing: Data Code may be changed
SET
Inverter is stopped, or is having the running frequency set
OV
Inverter is in an overvoltage condition
UV
Inverter is in an undervoltage condition