201
EXCLUSIVE BOILER GREEN HE B.S.I.
>6/@3UHRVWDODþUSDOQDYLãLQD
([FOXVLYH%RLOHU*UHHQ+(NRWOLVRRSUHPOMHQLVSUHWRþQRþUSDONRVVSUH
-
PHQOMLYRKLWURVWMRYUWHQMDLQMHåHKLGUDYOLþQRWHUHOHNWULþQRSRYH]DQDQMHQH
zmogljivosti so prikazane v diagramu.
.RWOLVRRSUHPOMHQLVSURWLEORNLUQLPVLVWHPRPNL]DåHQHGHORYQLFLNHOYVDNLK
XUNRVHNRWHOQHXSRUDEOMDQHJOHGHQDSRORåDMVWLNDOD]DXSUDYOMDQMH
»Protiblokirni« sistem kotla deluje le z vklopljenim glavnim napaja-
njem.
ýUSDONRMHVWURJRSUHSRYHGDQRYNORSLWLEUH]YRGH
1$67$9/-,9$+,75267ý53$/.(
)XQNFLMD UHJXOLUDQMD þUSDONH GHOXMH VDPR ] DNWLYLUDQLP SURJUDPRP RJUH
-
YDQMD ýUSDOND MH QD QDMYHþMR KLWURVW QDVWDYOMHQD V SUHNORSRP WULSRWQHJD
YHQWLODQDSORãþDWLWRSORWQLL]PHQMHYDOQLNDOLNRWHOKUDQLOQLNYRGH)XQNFLMR
UHJXOLUDQMDþUSDONHVHXSRUDEOMDVDPRVþUSDONRNRWODLQQH]YVDNRþUSDONR
]XQDQMLKSRYH]DQLKQDSUDYQSUWODþQDþUSDOND
1DYROMRVRQDþLQLGHORYDQMDPHGNDWHULPLL]EHUHWHQDMSULPHUQHMãHJDJOH
-
de na stanje in vrsto sistema.
= YQRVRP SDUDPHWUD Y WHKQLþQL PHQL ODKNR L]EHUHWH PHG QDVOHGQMLPL
PRåQRVWPL
635(0(1/-,9$ +,75267 ý53$/.( 9 352325&,21$/1(0
1$ý,18 3
635(0(1/-,9$+,75267ý53$/.(9.2167$171(01$ý,18
3
635(0(1/-,9$ +,75267 ý53$/.( 9 1$ý,18 1$67$9/-(1(
1$-9(ý-(+,75267,3
326(%1$8325$%$67$1'$5'1(ý53$/.(1(635(0(1/-,
-
9(+,75267,3
635(0(1/-,9$+,75267ý53$/.(9352325&,21$/1(01$ý,
-
18 3
9WHPQDþLQXNDUWLFDNRWODGRORþDNDWHUDNULYXOMDSUHWRNDVHERXSRUDELOD
JOHGHQDWUHQXWQRPRþNLMRNRWHOGREDYOMD
.UPLOQLNNRWODUD]GHOLREVHJPRþLVNDWHURNRWHOGHOXMHYRJUHYDOQHPQD
-
þLQXQDYHþUD]OLþQLKQLYRMHY(QDRGWHKKLWURVWLMHUD]SRORåOMLYD]OLQHDUQR
ORJLNRQDMYHþMDPRþ YHOLNDKLWURVWQDMPDQMãDPRþ PDMKQDKLWURVWVH
VDPRGHMQRL]EHUHQDSRGODJLPRþLNLMHYXSRUDELPHGRJUHYDQMHP
8SRUDEOMD VH Y YVHK VLVWHPLK NMHU MH PRþ NRWOD SUDYLOQR XUDYQRWHåHQD ]
dejanskimi potrebami sistema.
3UDNWLþQRSRYHGDQR
- Vstopite v parameter 90
- Nastavite parameter = 41
2320%$3URL]YDMDOHFSULSRURþDQDVWDYLWHYSDUDPHWUD
Vrednosti nad 41 se uporabljajo samo v posebnih primerih
635(0(1/-,9$+,75267ý53$/.(9.2167$171(01$ý,18
3
0RQWHUQDVWDYLYUHGQRVWǻ7NLQDMVHRKUDQMDPHGRGYRGRPLQSRYUDWQLP
YRGRPQSUþHMHQDVWDYOMHQDYUHGQRVWVHKLWURVWSUHWRþQHþUSDONHVSUH
-
PLQMDWDNRGDERVSUHWRNRPYVLVWHPXY]GUåHYDODǻ7QD&PHGYVWR
-
pom in izstopom).
.UPLOQLN GRORþL DOL QDM VH KLWURVW SUHWRþQH þUSDONH SRYHþD DOL ]PDQMãD V
WHPWXGLSUHWRNYVLVWHPXVNODGQR]YUHGQRVWPLNLMLKPHULOQLNQDWODþQHP
LQSRYUDWQHPYRGXUHGQRSUHYHUMDþHMHXJRWRYOMHQDYUHGQRVWǻ7QLåMDRG
QDVWDYOMHQHVHKLWURVW]PDQãDGRNOHUVHǻ7QHGRYROMSRYHþDGDGRVHåH
QDVWDYOMHQRYUHGQRVW1DVSURWQRSDKLWURVWVHSRYHþDþHXJRWRYOMHQDYUH
-
dnost presega nastavljeno.
8SRUDEOMD VH Y YLVRNRWHPSHUDWXUQLK VLVWHPLK RELþDMQR SUL QDGRPHVWLWYL
NMHUYVLVWHPXQLYJUDMHQWHUPRVWDWLQNMHUODKNRQDVWDYLWHL]UDþXQDQLǻ7
3RYSUHþQDWHPSHUDWXUDJUHOQLKWHOHVVHPHGGHORYDQMHPVVWDOQRWHPSH
-
UDWXURYWODþQHPYRGXLQNRMHVREQDWHPSHUDWXUDGRVHåHQD]YLãD=RKUD
-
QMDQMHPNRQVWDQWQHǻ7VH]]PDQMãDQMHPSUHWRNDVVSUHPHPERGHORYQH
NULYXOMH]QLåDWHPSHUDWXUDYSRYUDWQHPYRGXLQVWHPVSRGEXMDYLVRNRXþLQ
-
NRYLWRGHORYDQMHWHUSULKUDQHNSULSRUDELHOHNWULþQHHQHUJLMH
3UDNWLþQR
- Vstopite v parameter 90
- Vrednost parametra nastavite med 2 in 40
RELþDMQRPHGLQ
635(0(1/-,9$+,75267ý53$/.(91$ý,181$67$9/-(1(1$-
-
9(ý-(+,75267,3
9WHPQDþLQXQDVWDYOMLYDþUSDONDGHOXMHQHSUHNLQMHQR]QDMYHþMRKLWURVWMR
Uporablja se v sistemih z velikimi izgiubami obremenitve, kjer se mora to-
ploto kotla izkoristiti za zagotavljanje zadostnega pretoka (pretok v sistemu
pri maksimalni hitrosti manj kot 600 litrov/uro).
Uporablja se z grelnimi telesi z velikim pretokom v sistemu.
3UDNWLþQR
- Vstopite v parameter 90
- Nastavite parameter = 1
326(%1$8325$%$67$1'$5'1(ý53$/.(1(635(0(1/-,9(
+,75267,3
7DQDþLQVHPRUDXSRUDELWLYSRVHEQLKSULPHULKNMHUVHVNRWORP]DKWHYD
VWDQGDUGQHSUHWRþQHþUSDONHEUH]VSUHPLQMDQMDKLWURVWL3UHGSRVWDYLPRGD
MHELODþUSDONDVVSUHPHQOMLYRKLWURVWMRRGVWUDQMHQDLQVHMRMHQDGRPHVWLOR
V þUSDONR V NDWHUR KLWURVWL QL PRJRþH VSUHPLQMDWL 3R]RU NDUWLFR %(
povezana s spojnikom CN9, je treba odstraniti in nadomestiti s spojnikom
WHUPRVWLþNRPQDLVWHPVSRMQLNX&11DYHGHQDSRYH]DYDMHELVWYHQHJD
pomena za delovanje, brez tega lahko pride do nepravilnosti v delovanju
sistema.
3UDNWLþQR
- Vstopite v parameter 90
- Nastavite parameter = 0
.21),*85$&,-(.,-,+35,3252ý$352,=9$-$/(&
=81$1-,0(5,/1,.
DA
7(5025(*8/$
&,-$
=81$1-,0(5,/1,.
NE
%5(=7(5025(*8
/$&,-(
9,62.$
TEMPERATURA
(grelna telesa)
PROPORCIONALNA
(P90 = 41)
ǻ7NRQVWDQWQD
3
NIZKA
TEMPERATURA
(talno)
PROPORCIONALNA
(P90 = 41)
PROPORCIONALNA
(P90 = 41)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
100
200
300
400
500
600
700
800
900
1000
N:
N:
QDMYHþMH
QDMYHþMH
QDMPDQMãH
QDMPDQMãH
3UHRVWDODWODþQDYLãLQDPFD
3UHRVWDODWODþQDYLãLQDPFD
Pretok (l/h)
Pretok (l/h)
2%02ý-(
MODULACIJE
ý53$/.(
2%02ý-(
MODULACIJE
ý53$/.(
Summary of Contents for EXCLUSIVE GREEN HE 25 B.S.I.
Page 191: ...191 EXCLUSIVE BOILER GREEN HE B S I 52...
Page 205: ...205 EXCLUSIVE BOILER GREEN HE B S I...
Page 206: ...206 EXCLUSIVE BOILER GREEN HE B S I...