TABLE 1 (LED SIGNALS)
FUNCTIONING STATUS
FUNCTION INDICATOR
RELAY STATUS
STAND-BY, DIFFERENTIAL MODE
ONE FLASH, GREEN
OFF
STAND-BY, NORMAL ABSOLUTE MODE
ONE FLASH, GREEN
OFF
STAND-BY, ALTERNATIVE ABSOLUTE MODE
TWO FLASHES, GREEN
OFF
ON, HEAT REQUEST ACTIVE
ON, GREEN
ON
STORAGE CYLINDER TEMPERATURE SENSOR ERROR
FAST FLASHING, RED (*1)
OFF
SOLAR TEMPERATURE SENSOR ERROR
FAST FLASHING, RED (*2)
ON
(*1) In absolute thermostat mode, the storage cylinder sensor is not used and ignored.
(*2) The relay is activated and the pump switched on for safety purposes.
TABLE 2 (CONFIGURATION)
FUNCTIONING MODE
JUMPERS
FROST PROTECTION FUNCTION OFF
J1 REMOVED
FROST PROTECTION FUNCTION ON
J1 FITTED
DIFFERENTIAL THERMOSTAT
J2 REMOVED
ABSOLUTE THERMOSTAT
J2 FITTED
ABSOLUTE MODE NORMAL SETPOINT RANGE
J3 REMOVED
ABSOLUTE MODE ALTERNATIVE SETPOINT RANGE
J3 FITTED
TABLE 3 (FUNCTIONING PARAMETERS)
PARAMETER
VALUE
DIFFERENTIAL MODE TEMPERATURE DIFFERENTIAL
RANGE
2-20°C
ABSOLUTE MODE NORMAL SETPOINT RANGE
40-55°C
ABSOLUTE MODE ALTERNATIVE SETPOINT RANGE
0-90°C
DIFFERENTIAL MODE HYSTERESIS
3°C
ABSOLUTE MODE HYSTERESIS
3°C
FROST PROTECTION ON THRESHOLD
5°C
FROST PROTECTION OFF THRESHOLD
6°C
TABLE 4 (ELECTRICAL CONNECTIONS)
POSITION
DESCRIPTION
M1-A
PHASE (230V)
M1-B
NEUTRAL (230V)
M2-C
N.O. RELAY
M2-D
N.C. RELAY
M2-E
COMMON RELAY
M3-F
TEMPERATURE SENSOR 1
M3-G
TEMPERATURE SENSOR 1
M3-H
TEMPERATURE SENSOR 2
M3-I
TEMPERATURE SENSOR 2