Operating
Operating instructions
21
Control indicators
The control indicators on the control panel remind you
to perform certain maintenance tasks.
Control indicator: change the recirculated air filter/filling
This indicator blinks after every 350 hours of operation,
when the device is used in recirculated air mode.
Ø
Replace the recirculated air filter/filling
See page 29
To reset the indicator when you have changed the filter
filling and to reset the hour meter, proceed as follows:
Ø
Switch to configuration mode as described to the
side.
Ø
Briefly touch the touch pad
(power level 3).
The symbol of the touch pad
(power level 3) is
brightly lit and the blinking symbol to indicate that the
filter/filling must be changed is turned off.
Ø
Turn the configuration mode off.
Making settings in the configuration mode
You can adjust the following basic settings in the
configuration mode:
§
Activate control indicator
"Effect lighting" (with
touch pad
power level 1).This function is
deactivated on this device.
You can turn the effect lighting on and off by briefly
touching the touch pad
.
§
Activate control indicator
"extraction
mode/recirculated air mode" (with touch pad
power level 2)
You can change between extraction
mode/recirculated air mode after you have left the
configuration mode by briefly touching touch
pad
.
§
Reset control indicator
"change the recirculated
air filter/filling" (with touch pad
power level 3).
§
Turn on and off the automatic run-on function (with
touch pad
power level 4).
Turning on the configuration mode
To turn on the configuration mode, proceed as follows:
Ø
Ensure that the ventilation function is switched off.
Ø
Touch and hold touch pad
for more than 10
seconds until all the operating symbols blink five
times.
All the operating symbols blink five times. The
configuration mode is turned on.
Ø
Configure the settings as desired.
Turning off the configuration mode
To turn off the configuration mode, proceed as follows:
Ø
Briefly touch the touch pad
.