19
Bentone
172 515 14 2018-01-02
4.12 Setting Air damper
4.13 Air adjustment
The damper motor turns the damper between three pre-set positions:
fully closed, low load, full load. These positons are controlled in the motor
by cams of different colours. The black cam controls the gas valve for full
load. If the air volume needs changing: Remove the cover of the damper
motor and change the position of the cams by turning them with the tools
accompanying the burner.
4.14 Low load:
Adjust the operating switch to full load (ll).
-
* Reduce the air volume: Turn orange cam towards 0°
-
* Increase the air volume: Turn orange cam towards 90°
Adjust the operating switch back to low load and check the air volume.
4.15 Full load
Adjust the operating switch to low load.
-
Reduce the air volume: Turn red cam towards 0°
-
Inrease the air volume: Turn red cam towards 90°
If the red cam is moved, change the black cam as much. Adjust the
operating switch to low load and check that the correct air volume has been
obtained.
Note! The blue cam is the limit position for fully closed damper and it is
normally not necessary to change it.
Releasing button
By pressing the button and snapping it down, the motor will be released and
the damper can easily be turned. This function facilitates an exchange of
damper motor.
Releasing button
N.B! The upper position is
the standard position
t
High capacity (red)
Low capacity (orange)
Closed damper (blue)
Solenoid valve
High capacity (black)
Summary of Contents for BG 450-2
Page 2: ...2 Bentone...
Page 18: ...18 Bentone 4 11 Gas nozzle 45 Natural gas Propan Biogas UV detector...
Page 47: ...172 905 04 2018 02 15 12 EU Declaration of conformity Bentone Gasburners...
Page 50: ......
Page 51: ......
Page 52: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...