Expander Module
Install Expander Modules
as follows.
+
Expanders Modules must be installed befo-
re mounting the Control panel to the wall.
1.
Remove the screws (
4
) and open the Con-
trol panel.
2.
Insert the reverse locking supports (
93
) into
their respective locations (
94
) (as per
Fig. 10a).
3.
Fit the long spacer (
95
) onto the fixed screw
(
96
), as shown in Fig. 10b.
4.
Using a nut, secure the Expander Module in
position (as per Fig. 10c).
5.
Using the Jumper (
70
) set the Address of
the Expander Module (marked “ADDR” on
the PCB):
Jumper (
70
) IN = Expander Module nr. 1
Jumper (
70
) OUT = Expander Module nr. 2
6.
Using the Flat cables connect the Expander
Modules as follows:
7. if you are installing ONE Expander Mo-
dule
— connect it to the Main Board, via
the jacks (
84
and
64
respectively), as per
Fig. 11);
if you are installing TWO Expander Modu-
les —
connect Expander Module nr. 1 to
Expander Module nr. 2, via the jacks (
83
),
then connect Expander Module nr. 1 to the
Main Board, via the jacks (
58
and
63
re-
spectively), as per Fig. 11b.
+
The polarity of the Flat cable connectors
must be observed.
Expander Control Board
Install the Expan-
der Module as follows.
1.
Fit the short spacers (
99
) onto the soldered
screws (
98
), as shown in Fig. 10d.
2.
Using the nuts, secure the Expander Control Board
in position, as per Fig. 10e.
3.
Using the Flat cable, connect the Expander Control
Board to the respective Expander Module, via the
jacks (
72
) and (
8
), as per Fig. 11a and Fig. 11b.
+
The polarity of the Flat cable connectors must be
observed.
INSTALLING THE CONTROL PANEL
23
99
21
21
25
10
10
77
13
13
13
9
72
72
64
15 85
8
26 83 84
23 83
99
10
72
84
26
15
b)
a)
64
Figure 11
Connecting ONE Expander Module (
a
) Connecting
TWO Expander Modules (
b
):
7)
Control Board of Expander Module
nr. 2;
8)
and
15)
Flat cable for the connection between the Control
Board and Expander Module;
9)
Main Control Board;
10)
Control
Board of Expander Module nr. 1;
13)
Main Board;
21)
Expander
Module nr. 1;
23)
and
26)
Flat cable for connection to the Expander
Module;
25)
Expander Module nr. 2;
64)
Jack for the Expander Bo-
ard connection;
72
) Jack for the connection between the Control
Board and the respective Expander Module (on the component
side);
83)
Jack for the connection between Expander Module nr. 1
and Expander Module nr. 2;
84)
Jack for the connection between
the Expander Module and the Main Board;
85)
Jack for the Control
Board connection.
Summary of Contents for J408
Page 1: ...INSTALLATION MANUAL CONVENTIONAL F I R E PA N E L S 424 408...
Page 17: ...IDENTIFICATION OF PARTS 17 C N O N C 36 35 b...
Page 29: ...USER S INSTRUCTIONS CONVENTIONAL F I R E PA N E L S 424 408...
Page 52: ...44 Conventional Fire Panels J424 J408...
Page 61: ...QUICK GUIDE 53...
Page 62: ...54 Conventional Fire Panels J424 J408...
Page 63: ...QUICK GUIDE 55...