During the course of a day "Link On" and "Link Off"
must not
occur at the
exact same time, as the program reads this as an error. Exit from the win-
dow is not permitted and the message <<Time zones overlap!>> is dis-
played.
Example
If the security system must be armed from Monday through Friday from
19.00 to 07.00 of the following day, Saturday from 13.00 to 07.00 of the fol-
lowing Monday, the "Time link" window should read in the following way:
Time link
On:
Mon.19:00
Off:
Tue.07:00
Tue.19:00
Wed.07:00
Wed.19:00
Thu.07:00
Thu.19:00
Fri.07:00
Fri.19:00
Sat.07:00
Sat.13:00
Mon.07.00
Message:
Time link error
This means that the Central Station displays the message <<Time link er-
ror>> for example when it does not receive the "Link On" event before
19.00 on Monday or even when it receives the "Link Off" event before
07.00 on Tuesday. If the "Link Off" event is received before 19.00 on Tues-
day the Central Station does not consider this as error. After this hour a
new interval starts and from 19.00 through 07.00 of the following day the
security system should be linked on, therefore Link Off is considered as an
error.
Test
By selecting [Test] a window opens where it is possible to specify the
pause necessary between two
test events
, starting from the moment when
the program receives the first
+
The program considers test events, those events assigned to Test Type.
Map
By selecting [Map] a window opens where it is possible to select a map for
the customer, the customer’s position on the map can be indicated by an
icon.
Map
Select the
Map
field and the appropriate map from the menu displayed.
Use the cursor keys to move the map (quicken the procedure by keeping
the [Ctrl] key pressed and zoom-in and zoom-out on parts by pressing
keys [+] and [--] respectively).
CENTRAL STATION program