D-305831 BW-ODC
Installation Instructions
3
Option
Configuration Instructions
IMAGE BRIGHTNESS
Set the brightness of the image.
Optional settings: Normal (default) -3, -2, -1, +1, +2 and +3.
IMAGE CONTRAST
Set the contrast of the image.
Optional settings: Normal (default) -3, -2, -1, +1, +2 and +3.
2.5 Local Diagnostic Test
A.
Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see Figure 4, steps 1 - 3) and then press and release the tamper switch (see Figure 5). The LED will flash
for 60 seconds and then the detector will enter into 15 minutes' local diagnostic mode.
Note:
The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B.
Adjust the detector in the horizontal plane to cover the required protected area.
C.
Walk into the detectors field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90°
pattern. Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily
for 2 seconds as you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received signal
strength indication (see Table 2).
Table 2 – Received Signal Strength Indication
LED response
Reception
Green LED blinks
Strong
Orange LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
Important!
Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the
detector, re-locate it and re-test until a "Good" or "Strong" signal strength is received.
Note:
For detailed Diagnostics Test instructions refer to the control panel Installer's Guide.
The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds),
the control panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3).
Important!
Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector.
D.
Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED
lights continuously (see Table 3 below) and the alarm control panel receives the masking alarm.
E.
Remove the masking from the detector’s front side. Verify that the LED turns off after 30 seconds.
Table 3 – LED operation
LED Indications
Event
Red Alarm LED blinks
Stabilization (warm-up 60 sec)
Red Alarm LED ON 0.2 sec.
Tamper open / close
Red Alarm LED blinks twice
One quad PIR detection in diagnostic mode
Red Alarm LED on 2 sec.
Intruder alarm
Yellow Indication LED ON
AM detection – diagnostic mode
Yellow indication LED blinks slowly (0.2 sec. ON, 30 sec. OFF)
AM detection – Normal mode
3. COMPLIANCE WITH STANDARDS
The BW-ODC complies with the following standards:
Europe:
EN 300220, EN 301489, EN 62368-1, EN 60950-22, EN 50130-4, EN 50130-5, EN 50131-2-2, EN 50131-6, Type C, EN
50131-5-3, EN 50131-1 Grade 2 Class IV IP55
Hereby, Bentel Security S.r.l. declares that the radio equipment type BW-ODC is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.bentelsecurity.com/dc
.
UK:
This product is suitable for use in systems installed to conform to PD6662 at Grade 2 and environmental class 4. BS8243
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you originally purchased it. If you
are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This
product is not to be thrown away with everyday waste.
Directive 2012/19/EU Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
OPTICAL
Black Mirror Max. Coverage
Up to 12 m (40 ft) / 90°
Detector Technology
8 independent quad PIR detectors operating in true Quad configuration (See Figure 6 on page 16)
Pet Immunity
Small pets
ELECTRICAL
Input Power
Two 3V / 2400 mAh, CR17450 Lithium batteries manufactured by EVE/GP
Battery Life (for typical use)
3 years
Low Battery Threshold
4.0 V
Operation voltage
4 V to 6.5 V
Current consumption
Min: 30
μ
A Max: 550 mA
Optional Mains Supply
Additional to batteries, 7.5 V DC, 1.5 A