D-305831 BW-ODC
Installation Instructions
2
Notes:
1.
For installation options to reduce the probability of false alarms from pets, see the grayed-in cells in Table 1.
2.
For EN installations only and the distance ranges between 11 to 12 m (36 - 39ft), set the PIR sensitivity to "One region".
3. For situations where the beams are directed towards open space, the coverage distance specified in Table 1 - Vertical Adjustment
Reference may be exceeded.
2.2 Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see Figure 4 on page 15). After battery insertion, the LED will flash for
60 seconds and then the detector will enter a 15 minutes' local diagnostic mode.
2.3. Enrollment
Refer to the BW control panel's Installer Guide and follow the procedure under the
02:ZONES/DEVICES
option of the Installer Menu. A general
description of the procedure is provided in the following flow chart.
Step 1
Step 2
Step 3
Step 4
Enter the Installer menu and select
02:ZONES/DEVICES
Select
ADD NEW DEVICE
See Note 1
Enroll the device (see Figure 5 on
page 16) or enter the device ID
Select a detector number for
the new detector
02:ZONES/DEVICES
ADD NEW DEVICES
ENROLL NOW
or
ENTR ID:XXX-XXXX
Z09:Motion Camera
ID No. 142-XXXX
MODIFY DEVICES
Step 5
Step 6
Step 7
Configure Location, Zone Type and
Chime parameters
Enter
PARTITIONS
.
See Note 2
Assign partitions to the detector by
pressing
the ,
and/or
buttons on the
panel
Z09.LOCATION
Z09.ZONE TYPE
Z09.SET CHIME
Z09/PARTITIONS
Z09:P1
P2 P3
means scroll
and select
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the “Modify Devices” option – see Step
2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details,
see "Partitioning" in the BW Installer Guide).
2.4. Configuring the Detector Parameters
Enter the
DEVICE SETTINGS
menu and follow the configuration instructions for the BW-ODC PIR detector as described below.
Option
Configuration Instructions
ALARM LED
Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
PIR SENSITIVITY
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed
before an alarm is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note:
For EN compliance, the detector should be set to "One Region".
DISARM ACTIVITY
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES + 1m
delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
OUTDOOR ANTI-M
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
ALARM Hours
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
IMAGE COLOR
Define whether the image will be in black & white or color.
Optional settings: Black & White (default) and Color.
IMAGE RESOLUTION
Set the pixel quality of the image. Select 160 x 120 for lower quality or 320 x 240 for higher quality.
Optional settings: 320 x 240 (default) and 160 x 120.
IMAGE QUALITY
Set the quality of the image.
Optional settings: High (default) and normal.