PowerG, Outdoor Mirror PIR Motion Detector with Anti- masking and 
Built-In Camera

 

Installation Instructions 

 Italiano  

Rilevatore di movimento PIR a specchio, da esterno, con 
antimascheramento, e telecamera incorporata, PowerG 

Istruzioni di installazione 

 Polski 

 

Lustrzany czujnik ruchu PIR z funkcj

ą

 antymaskingu i wbudowan

ą

 

kamer

ą

, do zastosowa

ń

 zewn

ę

trznych

 

Instrukcja instalacji 

ENGLISH 

1. INTRODUCTION 

Note:

 Operations described in these instructions applies to BW control panels. For further information related to operations with a different 

control panel, refer to the control panel's instructions. 

The BW-ODC is a 2-way, wireless outdoor digital mirror PIR detector with built-in camera. Activated upon PIR detection or upon demand, the 
BW-ODC sends clear images to the Monitoring Station for alarm image verification. 

The PIR motion detector’s features are as follows: 

 

Operates with BW control panels (version 18 and higher) 

 

Patented 8 independent quad PIR detectors (Octa-QUAD

TM

) operating in true Quad configuration (patented) with true motion recognition 

(TMR) processing for each of the 8 PIR detectors 

 

Advanced Obsidian Black Mirror

TM

 optics (patent pending) 

 

Optimum performance even in poor weather conditions such as snow, rain, dust, wind, and direct sunlight 

 

Tamper protection prevents opening and removal from wall 

 

PowerG two-way Frequency Hopping Spread Spectrum FHSS-TDMA technology - provides robustness and reliability 

 

Built-in link quality indicators enable installer to check signal quality without physically approaching the control panel 

 

Robust housing with recessed window 

 

Smart anti masking distinguishes between masking spray and rain 

 

Alarm LED is visible in sunlight 

 

Automatic termination of walk-test after 15 minutes 

 

Microprocessor-controlled temperature compensation 

 

Immunity to small pets 

 

Built-in swivel bracket. 

The camera’s features are as follows: 

 

Up to 10 cameras can be enrolled 

 

Images multiplexed from all enrolled cameras 

 

Color and black & white images 

 Auto-setup 

 

Camera tuning by simple walk-test 

 

Day and night CMOS camera, with near IR illumination. This allows taking pictures in full darkness without letting the intruder know. 

 

Instant capture: guarantees capture of fast moving intruder. 

 

Optional AC power 

 

An event records 2 images per second. 10-15 images total 

2. INSTALLATION 

2.1 Installation 

A. 

Bracket installation (see Figure 2 on page 13). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must 
provide for the orientation of the detector to be as parallel as possible to the surveyed ground surface. 

B.

 Adjust the detector's horizontal and vertical angles (see Figure 3 on page 14), according to the surveyed ground surface. Set the vertical 

angle position depending on the mounting height and coverage distance that you require. See Figure 3 and Table 1 for details. The 
information refers to a relatively flat surveyed area. Verify the correct installation by using the walk test method. 

C. 

Fasten the detector to the bracket (see Figure 2 on page 13, step 4). 

D.

 To decrease false alarms, which can be triggered by pets, it is recommended to install the detector at a height of 2 to 2.5 meters from the 

ground surface. In addition, vertical adjustment must be fixed on #4 or #5 position. It is recommended to direct the detector on a 
background such as walls, houses, fences but not on open space. 

Installation Notes: 

The top cover should only be accessed by authorized service personnel or manufacturer. Do not obscure the detector field of view with large 
objects. Install in position such that expected intruder motion is perpendicular to the zones of detection. 
Alarms that could be triggered by conditions such as weather, blowing leaves and brush, or related environmental conditions, etc., need to be 
considered when assessing the installation and application. 

Table 1 – Vertical Adjustment Reference 

Mounting Height 

Nominal Coverage Distance

 

2m / 6.7ft

 

4m / 13ft

 

6m / 20ft

 

8m / 26ft

 

10m / 33 ft

 

12m / 39 ft

 

3.0m / 10 ft 

-  1 2 2 3 3 

2.5m / 8 ft 

1 1 2 3 4 

2.0m / 7 ft 

1 2 3 4 5 

1.5m / 5 ft 

2 3 4 5 5 - 

Summary of Contents for BW-ODC

Page 1: ...eras can be enrolled Images multiplexed from all enrolled cameras Color and black white images Auto setup Camera tuning by simple walk test Day and night CMOS camera with near IR illumination This all...

Page 2: ...ou can configure the detector parameters and assign partitions via the Modify Devices option see Step 2 2 PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports th...

Page 3: ...peration of the detector D Place a piece of cardboard on the detector s front side to deliberately mask the optical window Verify that after 2 minutes the yellow LED lights continuously see Table 3 be...

Page 4: ...ITIVE DAMAGES OR FOR LOSS DAMAGE OR EXPENSE INCLUDING LOSS OF USE PROFITS REVENUE OR GOODWILL DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTRUC...

Page 5: ...lazione A Installazione della staffa vedere Figura 2 a pagina 13 Fissare saldamente la staffa a una parete o a una colonna stabile L orientamento della staffa fissa deve essere il pi possibile paralle...

Page 6: ...ore funziona con una sensibilit PIR normale o alta oppure che almeno una zona di rilevazione deve essere attraversata prima che scatti un allarme una regione Opzioni BASSO impostazione predefinita ALT...

Page 7: ...settimana per verificare il corretto funzionamento del rilevatore D Posizionare un pezzo di cartone sul lato anteriore del rilevatore per mascherare intenzionalmente la finestra ottica Verificare che...

Page 8: ...DIO Banda di frequenza MHz 868 869 Potenza di trasmissione massima 14 dBm 868 MHz Protocollo di comunicazione PowerG Avviso sabotaggio Segnalato quando si verifica un evento di sabotaggio e in ogni tr...

Page 9: ...ika patrz Rysunek 2 na stronie 13 Przymocuj wspornik do mocnej ciany lub s upka Nale y zachowa r wnoleg o wspornika wzgl dem powierzchni kt ra b dzie monitorowana B Ustaw k t czujnika wzgl dem poziomu...

Page 10: ...lub wy czenie wskazania diody LED alarmu Ustawienia opcjonalne W domy lnie i WY CZULOSC PIR Umo liwia wyb r czu o ci PIR standardowej lub wysokiej a tak e konieczno ci przekroczenia co najmniej jednej...

Page 11: ...ona przez 2 sekundy do centrali jest wysy any alarm W razie potrzeby wyreguluj ustawienie czujnika w poziomie i pionie patrz punkt 2 1 i Rysunek 3 na stronie 14 Wa ne Nale y poinstruowa u ytkownika o...

Page 12: ...TRANSMISJI BEZPRZEWODOWEJ Pasmo cz stotliwo ci MHz 868 869 Maks moc nadawania 14 dBm przy 868 MHz Protok komunikacji PowerG Ostrze enie o sabota u Zg aszane po wyst pieniu nowe zdarzenia sabota u i p...

Page 13: ...alacja A Mark drilling point B Screw hole for wall tamper C Drill D Fasten E Three long screws F Two short screws Note The 2 screw holes enable adjustment of the bracket on the wall if needed followin...

Page 14: ...5 4 Release locking 5 Adjust 6 Lock A Vertical angle steps 4 Svitare la vite 5 Regolare 6 Bloccare A Passi dell angolo verticale 4 Zwolni blokad 5 Ustawi 6 Zablokowa A Stopniowa regulacja k ta wzgl de...

Page 15: ...not dispose of in fire D Agganciare in posizione la morsettiera Attenzione Rischio di esplosione qualora la batteria venisse sostituita con una batteria di tipo errato Smaltire la batteria usata in c...

Page 16: ...abota owy Figure 5 BW ODC Figura 5 BW ODC Rysunek 5 BW ODC A Top view B Side view of each detector C Image coverage range A Vista in pianta B Vista laterale di ciascun sensore C Copertura della teleca...

Reviews: