30
11/ 2019
BENNING CM 10–PV
MODE key (blue)
J
:
Setting the APO time to 5/10/20 min. or switching off
the APO function, “OFF” is shown on the display.
Each time the key is pressed again, the value changes.
MIN/MAX key
9
:
Unit of temperature in °C or °F
HOLD/ZERO key
5
:
Displaying all display symbols
HFR
8
Displaying the firmware version
5.1.14 Temperature coefficient of the measured value: 0.2 x (stated measuring
accuracy)/ °C < 18 °C or > 28 °C, related to the value for the reference
temperature of 23 °C.
5.1.15 The BENNING CM 10-PV is supplied by means of two 1.5 V batteries
(IEC LR6/ AA).
5.1.16 The battery indication
M
continuously shows the remaining battery ca-
pacity via a maximum of three segments. When switched on, the device
additionally displays the battery status “Full” (full), “HALF” (half) or “Lo”
(low).
As soon as all segments of the battery symbol have disappeared
and the battery symbol is flashing, the batteries must be re-
placed by new ones immediately in order to prevent danger for
persons caused by incorrect measurements.
5.1.17 The battery life is approximately 200 hours without using the display
illumination and the Bluetooth
®
function (alkaline battery).
5.1.18 Dimensions of the BENNING CM 10-PV: (L x W x H) = 240 x 86 x 48 mm
Weight: 445 g with batteries
5.1.19 Current clamp opening: 37 mm
5.1.20 The safety measuring leads supplied are expressly suited for the rated
voltage and the rated current of the BENNING CM 10-PV.
5.1.21 The BENNING CM 10-PV supports wireless data transmission via the
Bluetooth
®
4.0 standard to an Android or IOS device (smartphone/tab-
let).
5.2 Data logger functions
The
data logger (LOG)
allows the automatic and manual storage of series of
measurements with a predefined measuring interval (sampling rate) and up to
4000 measured values. The measuring interval can be set from 1 s to 60 s. The
measured values can be read out later via Bluetooth
®
for further processing.
5.2.1 Setting the data logger
To set the data logger, press the
Bluetooth
®
key
7
and simultaneously switch
on the BENNING CM 10-PV via the rotary switch
6
. The current setting is shown
by a symbol on the digital display
K
. As soon as the symbol appears, press the
Bluetooth
®
key
7
repeatedly to select from the following functions:
Symbol:
Function:
„LOG“
Automatic storage with predefined measuring interval
„SAVE“
Manual storage by pressing a key
„CLR“
Deleting the internal measured value memory
A selected function will be automatically accepted after 2 seconds and remains
permanently stored.