Dark area caused by thin film delamination is not allowed.
4.1.5
Bright spots in active area:
Bright spot in active area:
•
Size of extra luminous area must be <15% of segment area when
addressed to full ON.
•
Max. 1 per cm2 and max. 2 per glass.
4.1.6
Thin film defects
Scratches in thin films not allowed in active area, allowed outside active area if
remaining line width exceeds 1/3 of nominal.
Delamination not allowed in active area.
Thin films on outside side of TASEL glass not allowed (Thin film backside
growth).
5
Description of warranty
Warranty of the in-glass laminated product is specified by Beneq in the sales agreement
between Beneq and Customer.
SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
6
Ordering information
Product
Part number
Description
ELT160.60.100-07NC EL00045100
Transparent TFEL display of matrix type,
160 x 60 pixels, no cover glass (intended
for in-glass lamination), 4 FPCs and driving
electronics
7
RoHS II
Beneq Oy is committed to continuous improvement. As part of this process we are fully in
support of EU directive 2011/65/EU, the Restriction of Hazardous Substances, commonly
known as RoHS II or RoHS Recast, which, compared to RoHS, keeps the restrictions on the
original six hazardous substances, including lead (Pb) in electronic equipment. It also
expands these restrictions to previously exempted categories including medical devices and
monitoring and control instruments.
This document is compiled and kept up-to-date as conscientiously as possible. Beneq cannot, however, guarantee that the data are free of errors, accurate
or complete and, therefore, assumes no liability for loss or damage of any kind incurred directly or indirectly through the use of this document. The
information in this document is subject to change without notice. All texts, pictures, graphics and any other contents of this document and their layout are
protected by copyright and other protective laws. The aforementioned contents may not be duplicated, modified or used in other electronic or printed