Product Specifications and
Operations Manual
ELT160.60.100-07NC
Transparent Matrix Display
Beneq Oy
Olarinluoma 9
Tel. +358 9 7599 530
VAT ID FI25115461
FI-02200 Espoo
Fax +358 9 7599 5310
www.beneq.com
Finland
www.lumineq.com
Date: October 7, 2019
Document number: ED001129C
Page | 12
Figure 3. Display pixel locations on image data mapping.
3.5.3
Write display block (multiple rows)
Command First row
number
Last row
number
First bits of
first row
----
Last bits of
last row
02
h
8 bits
8 bits
8 bits
8 bits
8 bits
3.5.4
Write one row
Command Row number First bits of row ----
Last bits of row
03
h
8 bits
8 bits
8 bits 8 bits
3.5.5
Clear screen (full black)
Command
11
h
Fill the display frame memory with
‘0’.
3.5.6
All pixels ON (full yellow)
Command
12
h
Fill the display frame memory with
‘1’.
3.5.7
Invert display image
Invert command only inverts visible display picture and does not manipulate picture data on
display frame memory. Consecutive invert commands toggle displayed image between
inverted and non-inverted mode.
Command
13
h
3.5.8
Write frame frequency
Command
Relative Luminance
81
h
100 %
82
h
75 %
83
h
50 %
84
h
30 %